Memory switch functions

This printer unit has the following memory switches in non-volatile memory.
Msw 1, Msw 2, Msw 8

Customized values

Serial communication conditions

These settings can be set by GS ( E . Refer to Application Programming Guide for details of the
command.
Some settings of Msw 2 and Msw 8 can be set by the switch operation. (Refer to page 3-15)
MSW1
Bit
Function
1
Send power on notification.
2
Select receive buffer capacity.
3
Conditions for Busy status.
4
Data processing when reception
error occurs.
5
Automatic line feed
6
Revseved
7
#6 pin signal select for reset
8
#25 pin signal select for reset
MSW1-7, 1-8 are effective only when serial interface is used.
MSW2
Bit
Function
1
Reserved
2
Autocutter operation
3 - 8
Reserved
MSW8
Bit
Function
1 - 5
Reserved
6
Feeding paper to the print starting position at
power on
7
Reserved
8
Printer cover open during operating
If the print starting position is not set when power is turned on, the printing position of the first sheet may shift, or a
paper layout error may occur.
2-10 Setup
0 (OFF)
Yes
Large (4Kbyte)
Receive buffer full or
offline
Substitute with '?'
Invalid
Fixed to off
Not used
Not used
0 (OFF)
Disabled
Value
0 (OFF)
Enabled
Errors that automatically
recover
1 (ON)
No
Small (45byte)
Receive buffer full
Ignored
Valid
Used
Used
1 (ON)
Fixed to 1 (One)
(do not change
settings)
Enabled
1 (ON)
Disabled
Errors that can possible
recover
Rev. A