Outdoor Fan System Check; Capacitor Voltage Check - Daikin 3MKS50E3V1B Service Manual

Super multi nx e / f / g / k-series
Hide thumbs Also See for 3MKS50E3V1B:
Table of Contents

Advertisement

Check

8.13 Outdoor Fan System Check

Check No.19

8.14 Capacitor Voltage Check

Check No.21
Before this check, be sure to check the main circuit for short circuit.
With the circuit breaker still on, measure the voltage according to the drawing of the model in
question. Be careful never to touch any live parts.
334
Check the outdoor unit fan system.
Outdoor unit fan running?
YES
Outdoor unit fan
system
functioning.
Multimeter
(DC. voltage range)
NO
Fan motor lead wire
connector disconnected?
NO
Go to Check No. 16.
SiBE121135
YES
Reconnect the connector.
(R15128)
(R12869)
Service Diagnosis