SiBE121135
1.9
Removal of Compressor
Procedure
Step
1
Remove the terminal
cover.
2
Disconnect the
compressor lead wires.
3
Detach the overload
protector.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Terminal cover
V(yellow)
Overload protector
(R12914)
U(red)
W(blue)
(R5602)
(R12916)
(R5604)
Outdoor Unit: 40-75 Class
Points