Indoor Unit Control (RA Models)
<Heating / Radiant>
Wall Mounted Type: FTXG, FTXS-G series
Floor Standing Type: FVXG series
Wall Mounted Type: FTXS-K, CTXS-K, FTXS-J series
Floor Standing Type: FVXS series
Floor / Ceiling Suspended Dual Type, Duct Connected Type
Refer to "Temperature Control" on page 76 for detail.
88
OFF
A
B
1.5˚C
C
ON
OFF
A
B
1.0˚C
C
OFF
A
B
1.0˚C
C
Room thermistor temperature – target temperature
2.0˚C
0.5˚C
Room thermistor temperature – target temperature
1.5˚C
0˚C
ON
Room thermistor temperature – target temperature
1.5˚C
0.5˚C
ON
SiBE121135
(R11894)
(R12320)
(R12392)
Function and Control