PRODUCT FEATURES

This appliance has been certifi ed for use with either
natural or propane gas. See appropriate data plates.
This appliance is not for use with solid fuels.
The appliance is approved for bedroom or bedsitting
room installations.
The appliance must be installed in accordance with local
codes if any. If none exist use the current installation
code. ANSI Z223.1/NFPA 54 in the USA, CSA B149 in
Canada.
This appliance is mobile home approved.
The appliance must be properly connected to a venting
system.
The appliance is not approved for closet or recessed
installations.

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are certifi ed
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current ANSI
Z223.1/NFPA 54 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local author-
ities having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).

GAS PRESSURES

Inlet Minimum
Inlet Maximum
Manifold Pressure
ORIFICE SIZES
MODEL
FUEL
KHLDV400
NG
KHLDV400
LP
KHLDV500
NG
KHLDV500
LP
KHLDV600
NG
KHLDV600
LP
20306742
Natural
Propane (LP)
4.5" w.c.
11.0" w.c.
10.5" w.c.
13.0" w.c.
3.5" w.c.
10.0" w.c.
ORIFICE SIZE
FRONT
REAR
#49 (.073")
#35 (.110" )
#56 (.0465")
#52 (.0635")
2.3 mm
#30 (.1285)
#55 (.052")
#50 (.070")
2.35 mm
#20 (.161")
#54 (.055")
#49 (.073")
KHLDV Series Gas Fireplace
Figure 1 -
KHLDV Series Fireplace (shown with Millivolt)
GAS SPECIFICATIONS
MODEL
FUEL
KHLDV400NV
KHLDV400PV
KHLDV400NTSC
KHLDV400PTSC
KHLDV500NV
KHLDV500PV
KHLDV500NTSC
KHLDV500PTSC
KHLDV600NTSC
KHLDV600PTSC
Ignitor
MAX.
INPUT
INPUT
BTU/H
BTU/H
NG
40,000
28,500
LP
40,000
30,500
NG
40,000
28,500
LP
40,000
30,500
NG
50,000
35,500
LP
50,000
38,500
NG
50,000
35,500
LP
50,000
38,500
NG
60,000
41,500
LP
57,000
40,000
Access Panel
Blower
Control
(optional)
Light Control
Off/Pilot/On
Knob
Hi/Lo Knob
On/Off/RS
Switch
MIN.
5