Lighting Pilot - Vermont Castings KHLDV400PTSCSB Installation And Operating Instructions Manual

Khldv series direct vent gas fireplace
Table of Contents

Advertisement

KHLDV Series Gas Fireplace
LIGHTING PILOT FOR THE FIRST TIME
APPROVED LEAK TESTING METHOD
You may check for gas leaks with the following methods only:
• Soap and water solution
• An approved leak testing spray
• Electronic sniffer
Never check for gas leak with
open fl ame!
Check for gas leaks in each of the following locations:
• Pipe from the gas supply line connection to the gas valve
• Burner connections
• Pilot
• Each joint or connection
The control has an interlock device that does not allow the lighting of the fi replace
up to the moment the safety device of the fl ame has not interrupted the gas fl ow.
After that period of time (when the magnet is closed), it is possible to start the
lighting operation.
The gas control knob is designed to be operated by hand. DO NOT use any tools
during this operation. Damaged knobs may result in serious injury.
1. Depress and turn knob counterclockwise
to pilot position.
2. Depress fully and hold pilot gas knob. Depress
piezo igniter as many times as needed to ignite pilot.
Keep knob fully depressed for a few seconds.
Release and check that pilot continues to burn.
If the pilot does not stay lit, repeat steps 1 and 2.
28
MILLIVOLT: OPERATING INSTRUCTIONS
• Field made joints / gas shutoff valve
• Factory made joints
• All joints on valve and control body

LIGHTING PILOT

NOTE: Remove any excessive pipe
compound from the connections.
Excessive pipe compound can set off
electronic sniffers.
If using a soap and water
solution to test for leaks,
DO NOT spray solution onto
control body.
Pilot Position
P I L
O T
Continued on next page
20306742

Hide quick links: