Product Features; Operation; Gas Pressures; Gas Specifications And Orifice Sizes - Vermont Castings VFC24C Installation & Operating Instructions Manual

Vent free fireplace system
Table of Contents

Advertisement

PRODUCT FEATURES

Fireplace
Screen
On/Off Switch
Piezo Ignition
Control Knobs
Figure 1 -
VFC Shown with Control Access Door Open

OPERATION

This unvented gas heater requires no outside venting
and burns cleanly with excellent heating effi ciency. As a
zero-clearance appliance, it can be installed against (or
recessed into) any wall that is accessible to a gas line.

GAS PRESSURES

Control
Regulator Pressure
Pilot Regulator
Max. Inlet Pressure
Min. Inlet Pressure
Regulator Pressure
Max. Inlet Pressure
Min. Inlet Pressure
20308011
Fuel
Millivolt and IPI
Nat.
3.5" w.c.
Nat.
3.5" w.c.
Nat.
10.5" w.c.
Nat.
5.0" w.c.
LP
10.0" w.c.
LP
13.0" w.c.
LP
11.0" w.c.

GAS SPECIFICATIONS AND ORIFICE SIZES

MODEL
FUEL CONTROL
VFC24CNV NAT
MILLIVOLT 22,000 16,000
VFC24CPV
LP
MILLIVOLT 22,000 20,000
VFC24CNI
NAT
IPI
VFC24CPI
LP
IPI
VFC24LNV
NAT
MILLIVOLT 22,000 16,000
VFC24LPV
LP
MILLIVOLT 22,000 20,000
VFC24LNI
NAT
IPI
VFC24LPI
LP
IPI
VFC32CNV NAT
MILLIVOLT 28,000 19,000
VFC32CPV
LP
MILLIVOLT 27,000 22,000
VFC32CNI
NAT
IPI
VFC32CPI
LP
IPI
VFC32LNV
NAT
MILLIVOLT 28,000 19,000
VFC32LPV
LP
MILLIVOLT 27,000 22,000
VFC32LNI
NAT
IPI
VFC32LPI
LP
IPI
NOTE: For LP models an external regulator is required
to reduce supply pressure to a maximum of 13" w.c.

IGNITION CONTROLS

Piezo ignitor allows ignition of the pilot without the use of
matches or batteries.
Millivolt and EcoLogic
positions:
OFF - All gas to the gas logs is shut off at the
valve.
IGN - Valve position to light/maintain a standing

pilot.

ON - Valve position to turn ON/OFF log set with
remote switch/thermostat.
LOW/HI - Variable position to control fl ame height
(heat output).
PILOT
The gas log heater is fi tted with a specially designed safety
pilot light (ODS assembly) which senses the amount of
oxygen available in the room and shuts the gas log heater
off if the oxygen level begins to drop below a satisfactory
level. The pilot can only be re-lit when adequate fresh air
is available.

THERMAL GENERATOR

The millivolt gas log pilot is fi tted with a millivolt generator
to provide power for remote activation.
VFC Vent Free Fireplace System
MAX
MIN
BTU
BTU
22,000 16,000
22,000 20,000
22,000 16,000
22,000 20,000
28,000 19,000
27,000 22,000
28,000 19,000
27,000 22,000
®
2.0 controls have four (4)
ORIFICE
SIZE
2.35mm
1.45mm
2.35mm
1.45mm
2.35mm
1.45mm
2.35mm
1.45mm
#38
#52
#38
#52
#38
#52
#38
#52
5