FINAL INSTALLATION
ROCK WOOL PLACEMENT —
400/500 SERIES
1. Place rock wool on the front burner to provide glowing
embers. For best results, pull the rock wool apart into
dime size pieces and place on top of burner. Also place
the same size ember over the carry over parts on the
rear burner. Do NOT place embers over open slots
on the rear burner.
2. Distribute one layer of rock wool to cover the burner.
Figure 61
3. Place the logs on the burner. Refer to Log Placement
below. Light unit and after 15 minutes, check burner
fl ame and glow. Refer to Burner Flame, Page 53.
Figure 61 -
Rockwool placement - 400/500 Series
Do not use the entire bag of rock wool to
cover the burner. This could cause the fl ame
to burn poorly and may lead to sooting.
20306742
ROCK WOOL PLACEMENT— 600 SERIES
Place rock wool evenly in dime-sized pieces over front
burner both in front and behind grate. For the rear burner,
place the rock wool only on the carry-over areas between
the fl ames. To better enable the gas to permeate the rock
wool, apply the rock wool in light, fl uffy pieces.
Figure 62 -
Rockwool Placement - 600 Series
FP2155
KHLDV Series Gas Fireplace