Oki Data CONFIDENTIAL
1.5.5 Parallel interface specifications (Parallel installed
Model only)
1.5.5.1
Parallel interface overview
Item
Supported modes
Compatible mode, nibble mode, ECP mode
Data bit length
Compatible mode: 8 bit, Nibble mode: 4 bit, ECP mode: 9 bit
1.5.5.2
Parallel interface connector and cable
(1) Connector
Printer: 36-pole connector (female)
Product equivalent to RS6-36SKAAB4L00 (FU-YAO Tec. Co.,ltd.)
18
36
Connector pin arrangement
Cable:
36-pole connector (male)
(2) Cable
Use a cable of 1.8 m or less.
(Use a shielded twisted-pair cable for noise prevention.)
1.5.5.3
Parallel interface signals
Pin No.
Signal name
direction
1
DATA STROBE
2-9
DATA BIT - n
10
ACKNOWLEDGE
11
BUSY
12
PAPER END
13
SELECT
45487001TH Rev.1
Details
1
19
Signal
Compatible
Nibble
ECP
→ PR
nStrobe
HostClk
HostClk
→ PR
Data 1 (LSB) - 8 (MSB)
← PR
nAck
PtrClk
PeriphClk
← PR
Busy
PtrBusy
PeriphAck
← PR
Perror
AckDataReq
nAckReverse
← PR
Select
Xflag
Xflag
Signal
Pin No.
Signal name
direction
→ PR
14
AUTO FEED
15
-
-
16
0V
-
CHASSIS
17
GROUND
-
← PR
18
+5V
19
0V
-
20-27
0V
-
28
0V
-
29
0V
-
30
0V
-
→ PR
31
INPUT PRIME
← PR
32
FAULT
33
0V
-
34
-
-
← PR
35
Hi Level
→ PR
36
SEL-IN
1.5.5.4
Parallel interface levels
Low level: 0.0V to +0.8V
High level: +2.4V to +5.0V
1. Configuration
Compatible
Nibble
ECP
nAutoFd
HostBusy
HostAck
-
Logic Gnd
Chassis Gnd
Peripheral Logic High
Signal Ground (nStrobe)
Signal Ground (Data 1-8)
Signal Ground (Perror,Select,nAck)
Signal Ground (Busy,nFault)
Signal Ground (nAutoFd,nSelectIn,nInit)
nReverse-
nInit
nInit
Request
nPeriph-
nFault
nDataAvail
Request
-
-
Pulled up to +5V through 3.3Kohm
nSelectIn
1284 Active
1284 Active
1-11 /