Oki B721 Maintenance Manual page 158

Table of Contents

Advertisement

Oki Data CONFIDENTIAL
Panel display
Cause
Service Call
High-voltage power
121: Error
supply I/F error.
Service Call
Low-voltage power
122: Error
supply FAN error.
Low-voltage power
supply temperature
error.
Service Call
Abnormal
123: Error
environment humidty
/Not connected
humidity sensor.
Service Call
Abnormal
124: Error
environment
temperature.
Power Off/On
Condensation in
126: Error
the printer was
detected.
Service Call
Error detected at the
127: Error
fuser unit cooling
FAN.
45487001TH Rev.1
Check details
Solution
Result
Is cable between PU
No
Connect properly.
board and high-voltage
Yes
Check improper
power unit connected
connections for
properly?
high-voltage.
Is there no improperly
No
Replace the hige-
connections?
voltage power
supply.
Is the FAN (bottom
No
Check connections
right of the front) of
for connector of
the low voltage power
the FAN.
supply block working?
Yes
Replace the low-
voltage power
supply.
Is the FAN connector
No
Replace the FAN.
connected correctly?
Yes
Replace the low-
voltage power
supply.
Power Off/On.
Does error reoccur?
Yes
Replace the control
panel board (PCQ
board).
Power Off/On.
Does error reoccur?
Yes
Replace the control
panel board (PCQ
board).
Condensation iss likely
After leaving the
to occur in printers
printer at room
carried from the outside.
temperature, turn
Turn on the printer
on the power
again after it is exposed
again.
to room temperature for
two hours to half a day.
Does the error reoccur? Yes
Replace the control
panel board (PCQ
board).
Is the FAN connector
No
Connect properly
connected properly?
again.
Yes
Replace the FAN
motor.
Does error reoccur?
Yes
Replace the PU/
CU board.
Panel display
Cause
Service Call
Error detected at the
128: Error
engine FAN motors.
05: Fuser side FAN
08: REAR FAN
0B: ID FAN 2
Service Call
LED head fault
134: Error
detected.
(134=K)
Service Call
Fuser unit
155: Error
fuse cannot be
disconnected.
Service call
Error detected
163: Error
by toner sensor.
(163=K)
This error does
not occur with the
factory default
settings.
6. Troubleshooting procedure
Check details
Solution
Result
Is the FAN connector
No
Connect properly
connected properly?
again.
Yes
Replace the FAN
motor.
Does error reoccur?
Yes
Replace the PU/
CU board.
Is LED head properly
No
Set properly for
set?
LED head unit.
Yes
Turn power ON
agein.
Does error reoccur?
Yes
Replace LED head
unit
Is fuser unit set
No
After cleaning for
properly?
fuser connector,
reset.
Yes
Turn power ON
again.
Does error reoccur?
Yes
Replace the PU/
CU board.
Is toner cartridge
No
Set toner cartridge.
setting?
Is toner lock lever
No
Turn a lock lever
setting?
of toner to a fixed
Does error reoccur?
position.
Yes
Replace toner
sensor or
assembly.
6-25 /

Advertisement

Table of Contents
loading

This manual is also suitable for:

B731Mps5501bEs7131

Table of Contents