10-1. Parallel Interface Model
ON
OFF
No. 1 2 3 4 5 6 7 8
Switch 1-1
ON
OFF
ON
OFF
The factory settings of DIP switch are all on.
The functions of switches 1-3 through 1-10 will change according to the command emulation
that has been set using switch 1-1 and 1-2.
(1) Star Line Mode
Switch
1-1
Command emulation
1-2
Command emulation
1-3
Should not be changed (Should be set to on)
1-4
Sensor adjustment
1-5
Pin #31 (INIT) reset signal
1-6
Handshaking conditions
(conditions for BUSY)
1-7
ASB function *1
1-8
NSB function *2
1-9 ~1-10
Should not be changed (Should be set to on)
(2) Star Page Mode
Switch
1-1
Command emulation
1-2
Command emulation
1-3
Should not be changed (Should be set to on)
1-4
Sensor adjustment
1-5
Pin #31 (INIT) reset signal
1-6
Handshaking conditions
(conditions for BUSY)
1-7
ASB function *1
1-8
NSB function *2
1-9 ~1-10
Should not be changed (Should be set to on)
9 10
DIP-SW 1
DIP-SW 1
Switch 1-2
ON
ON
OFF
OFF
Function
Function
ON
OFF
No. 1 2 3 4
DIP-SW 2
Command emulation
Star Line Mode
Star Page Mode
-
ESC/POS Mode
Always ON
Always ON
Invalid
Valid
Offline or receive
buffer full
Invalid
Invalid
Always OFF
Always ON
Invalid
Valid
Offline or receive
buffer full
Invalid
Invalid
– 37 –
ON
Valid
Invalid
Receive buffer full
Valid
Invalid
ON
Valid
Invalid
Receive buffer full
Valid
Invalid
OFF
OFF