B. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
15-1/8 in.
(384 mm)
12 in.
(305 mm)
6-11/16 in.
(169 mm)
3-15/16 in.
(101 mm)
8 in.
(203 mm)
SL-2DVP
Adapter
14-7/16 in.
367 mm
14-7/16 in.
367 mm
SLP-WT-BK
Wall Thimble-Black
26 in.
660 mm
DVP-HSM-B
Extended Heat Shield
Figure 16.9 SLP Series Vent Components
80
8 in.
(203 mm)
Effective
SLP-TRAP
Horizontal Termination Cap
3-15/16 in.
(101 mm)
3-13/16 in.
(97 mm)
2-5/16 in.
59 mm
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. U • 7/12
Heat
Shield
Term Cap
Max
Trap1
Length
Trap2
6-3/8 in.
163 mm
4 in.
102 mm
5-1/16 in.
8-1/8 in.
(128 mm)
206 mm
2-3/4 in.
(70 mm)
DVP-FBHT
SL-2DVP
SLP90
Minimum
Maximum
Effective Length
Effective Length
3-1/8 in.
4-3/4 in.
79 mm
121 mm
5-1/4 in.
9-1/4 in.
133 mm
235 mm
4-5/8 in.
117 mm
DVP-2SL
Adapter
9 in.
(229 mm)
11-1/2 in.
(292 mm)
12-1/4 in.
(311 mm)
16 in.
(406 mm)
PVK-80
(For use with IPI and DSI appliances only.)
4-3/16 in.
106 mm
5-1/16 in.
128 mm
12-1/2 in.
(318 mm)
DVP-FBHT

Hide quick links: