Advertisement

Models:
SL-750TRS-C
SL-550TRS-C
SL-350TRS-C
WARNING: IF THE INFORMATION
IN THESE INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUS-
ING PROPERTY DAMAGE, PER-
SONAL INJURY, OR DEATH.
- Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
- Installation and service must be performed by a
qualified installer, service agency, or the gas
supplier.
Printed in U.S.A. Copyright 2003,
Heat-N-Glo, a brand of Hearth & Home Technologies Inc.
20802 Kensington Boulevard, Lakeville, MN 55044
This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322;
4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia)
543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT WITH APPLIANCE FOR
FUTURE REFERENCE.
WARNING: IMPROPER INSTALLA-
TION, ADJUSTMENT, ALTERATION,
SERVICE OR MAINTENANCE CAN
CAUSE INJURY OR PROPERTY DAM-
AGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFOR-
MATION CONSULT A QUALIFIED IN-
STALLER, SERVICE AGENCY , OR THE
GAS SUPPLIER.
1. This appliance may be installed in an af-
termarket, permanently located, manufac-
tured (mobile) home, where not prohibited
by local codes.
2. This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with
other gases, unless a certified kit is used.
Please contact your Heat-N-Glo dealer with any
questions or concerns. For the number of your nearest
Heat-N-Glo dealer, please call 1-888-427-3973.
1
Installers Guide
Underwriters
Laboratories Listed
534-985I 8/03

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo SL-750TRS-C

  • Page 1 Models: Installers Guide SL-750TRS-C SL-550TRS-C SL-350TRS-C Underwriters Laboratories Listed READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS WARNING: IF THE INFORMATION GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE. IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR...
  • Page 2: Safety And Warning Information

    SAFETY AND WARNING INFORMATION These units MUST use one of the vent systems READ and UNDERSTAND all instructions carefully described in the Installing the Fireplace section of before starting the installation. FAILURE TO the Installers Guide. NO OTHER vent systems or FOLLOW these installation instructions may result components MAY BE USED.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety and Warning Information ............2 Service Parts Lists ................4 Section 1: Approvals and Codes ............ 10 Appliance Certification ............... 10 Installation Codes ................10 High Altitude Installations ..............10 Section 2: Getting Started .............. 11 Introducing the Heat-N-Glo Gas Fireplaces .........
  • Page 4: Service Parts Lists

    SL-350TRS-C Service Parts Beginning Manufacturing Date: 2-01 (NG, LP) Exploded Parts Diagram Ending Manufacturing Date: ______ (GN, PL) Vue éclatée des pièces Log Set Assembly * Part number list on following page. * La liste des numéros de pièce se trouve à...
  • Page 5 SL-350TRS-C (NG, LP) S ervice Parts List / Liste des pièces de rechange IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order- ing, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 6: Log Set Assembly

    SL-550TRS-C Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 2-01 Ending Manufacturing Date: ______ (GN, PL) Vue éclatée des pièces 7 Log Set Assembly * Part number list on following page. * La liste des numéros de pièce se trouve à...
  • Page 7 (NG, LP) Service Parts List / Liste des pièces de rechange SL-550TRS-C IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 8 SL-750TRS-C Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 2-01 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ 7 Log Set Assembly * Part number list on following page. * La liste des numéros de pièce se trouve à la...
  • Page 9 SL-750TRS-C (NG, LP) Service Parts List / Liste des pièces de rechange IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When order- ing, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période.
  • Page 10: Section 1: Approvals And Codes

    Input MODELS: SL-750TRS-C, SL-550TRS-C, SL-350TRS-C rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. or 10% for elevations...
  • Page 11: Section 2: Getting Started

    Getting Started Introducing the Heat-N-Glo Gas Fireplaces The Heat-N-Glo Warranty will be voided by, and Heat-N-Glo disclaims any responsibility for, the following actions: Heat-N-Glo direct vent gas fireplaces are designed to oper- • Installation of any damaged fireplace or vent system ate with all combustion air siphoned from outside of the component.
  • Page 12 (90mm) (55mm) 36-1/8 GAS LINE (917mm) ACCESS 6-7/8 5-1/16 (174mm) 40-15/16 (129mm) (1040mm) TOP STANDOFFS VENT COLLARS HOOD CERAMIC FIBER PAD RATING PLATES & LABELS BOTTOM GRILLE GAS LINE ELECTRICAL COVER ACCESS CONTROLS ACCESS Figure 1. Diagram of the SL-750TRS-C...
  • Page 13 25-11/16 (653mm) (13mm) 12-7/8 (326mm) 16-3/8 15-7/8 (414mm) (402mm) 8-13/16 (223mm) Ø8 (203mm) Ø6-5/8 (168mm) 35-7/16 32-9/16 (901mm) (828mm) 21-7/16 (545mm) 32-1/8 (815mm) 3-1/3 2-1/8 (90mm) (55mm) 31-1/8 ELECTRICAL GAS LINE (790mm) 5-1/16 ACCESS ACCESS (129mm) 6-7/8 (913mm) (174mm) TOP STANDOFFS VENT COLLARS HOOD CERAMIC...
  • Page 14 22-3/4 (576mm) (13mm) 11-15/16 (288mm) 16-1/4 15-3/4 (413mm) (400mm) 8-13/16 (223mm) Ø 6-5/8 Ø 8 (168mm) (203mm) ELECTRICAL 30-5/8 ACCESS 30-1/8 (777mm) 34-7/16 (764mm) 15-1/4 (875mm) (388mm) 3-1/2 2-1/8 (90mm) (55mm) 28-1/8 GAS LINE (714mm) 6-7/8 ACCESS (174mm0 5-1/16 (837mm) (129mm) TOP STANDOFFS VENT COLLARS...
  • Page 15: Section 3: Installing The Fireplace

    Sides ..........1/2 ..13 seal gaps. Gas line holes and other openings should be *Top (SL-750TRS-C) ..... 3 1/4 ..83 caulked or stuffed with insulation. If the unit is being in- (SL-550TRS-C, SL-350TRS-C) .. 1 1/2 ..38 stalled on a cement slab, we recommend that a layer of Ceiling** ........
  • Page 16: Step 2 Framing The Fireplace

    Framing should be constructed of 2 X 4 VENT lumber or heavier. FRAMING The framing headers HOLE may rest on the fireplace stand-offs. Model SL-750TRS-C 42” 38 1/4” 16 1/4” 41” 27 7/8” SL-550TRS-C 37” 33” 16 1/4” 36 1/2” 24 3/8”...
  • Page 17 DVP4 DVP6 DVP12 14-1/4 12-3/16 MAX. MIN. DVP12A 9-7/8 DVP24 45.0 10-1/4 DVP45 DVP36 11-1/4 7-1/4 1-1/4 TYP DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES (34.93mm) AT EACH JOINT. Figure 6. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe)
  • Page 18 6 1/2 6 3/8 9 1/4 6 1/2 9 5/8 6 3/8 6 5/8 SL-45D 6 5/8 9 5/8 SL-90D SL-09D SL-12/17D (SL12-17D) SL-24D SL-48D SL-36D 8 3/4 12-17 23 3/4 35 3/4 47 3/4 17-24 6 1/2 11 3/4 5 3/4 6 5/8 SL-17/24D...
  • Page 19: Step 3 Installing The Vent System

    Step 3. Installing the Vent System WARNING: YOU MUST NOT MIX DVP-SERIES AND SL D-SERIES COMPONENTS IN ANY VENT A. Vent System Approvals SYSTEM CONFIGURATION. These models have vent starting collars on both the top and the back of the unit. Depending upon the installation, Identifying Vent Components decide which ONE set of starting collars will be used to Approved vent system components are labeled for identifi-...
  • Page 20 Flex Vent The flex vent must be supported with the spacing between STRAIGHT UP support intervals not exceeding 4 feet, with no more than ½ VERTICAL VENTING inch sag between supports. V (FT.) A support is required at each change in venting direction, 45' MAX.
  • Page 21 H MAX. = 16 FT (4.8m) V + H MAX. = 40 FT (12.2m) VENTING WITH ONE (1) 90 ELBOW PROPANE MODELS: SL-350TRS-C, SL-550TRS-C, SL-750TRS-C V (MIN.) H (MAX.) NOTE: There MUST be a 25% Elbow on Top NOT ALLOWED...
  • Page 22 H + H 1' MIN. (305 mm) 2' MAX. (610 mm) 4' MAX. (1.22m) 2' MIN. (610 mm) 4' MAX. (1.22 m) 8' MAX. (2.4m) 3' MIN. (914 mm) 6' MAX. (1.86 m) 12' MAX. (3.6m) 4' MIN. (1.22 m) 8' MAX.
  • Page 23 MAX. = 16 FT (4.8m) V + H + H MAX. = 40 FT (12.2m) VENTING WITH TWO (2) 90 ELBOWS PROPANE MODELS: SL-350TRS-C, SL-550TRS-C, SL-750TRS-C V (MIN.) H + H (MAX.) Elbow on Top NOT ALLOWED 1 FT (305mm)
  • Page 24 H MAX. = 16 FT (4.8m) V + V + H MAX. = 40 FT (12.2m) VENTING WITH TWO (2) 90 ELBOWS PROPANE MODELS: SL-350TRS-C, SL-550TRS-C, SL-750TRS-C V (MIN.) H (MAX.) Elbow on Top NOT ALLOWED 1 FT (305mm) 2 FT (610mm) 2 FT (610mm) 4 FT (1.22m)
  • Page 25 H + H 1' MIN. (305 mm) 2' MAX. (610mm) 4' MAX. (1.22m) 2' MIN. (610 mm) 4' MAX. (1.22m) 8' MAX. (2.48m) 3' MIN. (914 mm) 6' MAX. (1.86m) 12' MAX. (3.72m) 4' MIN. (1.22 m) 8' MAX. (2.48m) 16' MAX.
  • Page 26 16 FT (4.8m) 16 FT (4.8m) V + H + V MAX. = 40 FT (12.2m) VENTING WITH THREE (3) 90 ELBOWS PROPANE MODELS: SL-350TRS-C, SL-550TRS-C, SL-750TRS-C V (MIN.) H (MAX.) H + H (MAX.) Elbow on Top NOT ALLOWED...
  • Page 27 VENTING WITH THREE (3) 90 ELBOWS NATURAL GAS MODEL SL-550TRS-C MODEL SL-750TRS-C V (MIN.) H + H (MAX.) H + H (MAX.) Elbow on Top 2 FT (610mm) 2 FT (610mm) 1 FT (305mm) 3 FT (914mm) 3 FT (914mm) 2 FT (610mm) 4 FT (1.22m)
  • Page 28 90° VENTING WITH FOUR (4) ELBOWS NATURAL AND PROPANE GAS V (MIN.) H (MAX.) (MIN.) (MAX.) (MIN.) 2' (609mm) 5' (1.52m) 5' (1.52m) 5' (1.52m) 4.5' (1.37m) V + V + H + H MAX. = 40' (12.2m) Use SL D-Series components only.
  • Page 29: Installing Vent Components

    B. Installing Vent Components DVP Series Venting Only: After determining which set of starting collars will be used 1. Attaching the Venting to the Fireplace (top or rear), follow venting instructions accordingly. Refer to Cinch Pipe and Termination Cap installation in- NOTE: The SL-350TRS-C and SL-350TRS-C LP are built with structions.
  • Page 30 SL-D and SL-Flex Series Venting Only: 1. Attach the First Vent Component to the Starting Collars To attach the first vent component to the starting collars of the fireplace: • Lock the vent components into place by sliding the con- centric pipe sections with four (4) equally spaced interior beads into the fireplace collar or previously installed com- ponent end with four (4) equally spaced indented sections.
  • Page 31 DVP, SL-D and SL-Flex Series Venting: For Vertical Runs - One ceiling firestop is REQUIRED at the hole in each ceiling through which the vent passes. STEP 4. Install Firestops To install firestops for vertical runs that pass through ceilings: For Horizontal Runs - Firestops are REQUIRED on both sides of a combustible wall through which the vent passes.
  • Page 32: Vent Termination

    C. Vent Termination If the area above the ceiling is NOT an attic, position and secure the ceiling firestop on the ceiling side of the previously SL-Series Venting Only: cut and framed hole. For Horizontal Terminations - To attach and secure the termination to the last section of horizontal vent: •...
  • Page 33 (See Note 2) U.S. (3 FT) Electrical Service J or K = VENT TERMINAL = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED = 12" ......clearances above grade, ve ran- = 3 ft. (U.S.A.) (See Note 1) da, porch, deck or balcony 6 ft.
  • Page 34 For Vertical Terminations - To locate the vent and install To seal the roof hole, and to divert rain and snow from the the vent sections: vent system: • Locate and mark the vent centerpoint on the underside • Attach a flashing to the roof using nails, and use a non- of the roof, and drive a nail through the centerpoint.
  • Page 35: Positioning, Leveling, And Securing The Fireplace

    Step 4. Positioning, Leveling, and Step 5. The Gas Control Systems Securing the Fireplace WARNING: THIS UNIT IS NOT FOR USE WITH The diagram below shows how to properly position, level, SOLID FUEL. and secure the fireplace. The type of gas control system used with this model: Standing Pilot Ignition.
  • Page 36: Step 6 The Gas Supply Line

    Step 7. Gas Pressure Requirements Step 6. The Gas Supply Line NOTE: Have the gas supply line installed in accordance Pressure requirements for Heat-N-Glo gas fireplaces are with local building codes by a qualified installer shown in the table below. approved and/or licensed as required by the locality.
  • Page 37: Step 8 Wiring The Fireplace

    REMOTE SWITCH 3/16” PIGGYBACK CONNECTOR PIGTAIL BLACK S2 ON/OFF WHITE T2 SWITCH GAS VALVE RED T1 THERMOPILE BLACK S1 THERMOCOUPLE OPTIONAL WALL SWITCH, THERMOSTAT OR REMOTE Figure 35. Standing Pilot Ignition Wiring Diagram Step 8. Wiring the Fireplace Optional Accessories NOTE: Electrical wiring must be installed by a licensed electrician.
  • Page 38: Step 9 Finishing

    CAUTION: IF JOINTS BETWEEN THE FINISHED WALLS Step 9. Finishing AND THE FIREPLACE SURROUND (TOP AND SIDES) Figure 37 shows the minimum vertical and corresponding ARE SEALED, A 300° F. MINIMUM SEALANT MATE- maximum horizontal dimensions of fireplace mantels or other RIAL MUST BE USED.
  • Page 39: Step 10 Installing Trim, Logs, And Ember Material

    Slide shipping support to side, remove and discard. (BOTH TOP AND BOTTOM) • Lower grate onto refractory. GLASS ASSEMBLY Figure 40. Glass Assembly GLASS SPECIFICATIONS: SL-750TRS-C 24 5/8 x 35 3/8 CERAMIC Figure 39. SL-550TRS-C 21 1/8 x 30 3/8 CERAMIC SL-350TRS-C 19 x 21 1/2...
  • Page 40: Step 11 Before Lighting The Fireplace

    A small amount of air will be in the gas supply lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the fireplace will light and will operate normally. Subsequent lightings of the fireplace will not require this purging of air from the gas supply lines, unless the gas valve has been turned to the OFF position, in which...
  • Page 41: Section 4: Maintaining And Servicing Your Fireplace

    Maintaining and Servicing Your Fireplace Fireplace Maintenance Cleaning Glass Door Although the frequency of your fireplace servicing and main- Frequency: After the first 3 to 4 hours of use. As neces- tenance will depend on use and the type of installation, you sary after initial cleaning.

This manual is also suitable for:

Sl-550trs-cSl-350trs-c

Table of Contents