Heat & Glo SL-550TR-E Owner's Manual page 55

Hide thumbs Also See for SL-550TR-E:
Table of Contents

Advertisement

BATTERY PACK
Figure 12.2 Intellifi re Ignition Wiring Diagram with Wall Switch or Thermostat
NOTE: 1. Ignition module, valve, pilot, and
wall switch operate on 3 volts. 120 VAC is
required at junction box unless equipped
with battery back-up.
BATTERY PACK
PLUG IN
Figure 12.3 Intellifi re Ignition Wiring Diagram with Remote Receiver
IGNITION MODULE 3 VAC
TRANSFORMER
3 VAC
PLUG IN
WIRES
(TO BROWN)
THERMOSTAT
WIRE ASSEMBLY
TRANSFORMER
3 VAC
PLUG IN
REMOTE
Heat & Glo • SL-550 / 750 / 950TR-E • 2118-900 Rev. U • 7/12
INTERMITTENT PILOT IGNITOR
I
S
NOTE: 1. Ignition module, valve, pilot, and
wall switch operate on 3 volts. 120 VAC is
required at junction box unless equipped
with battery back-up.
WHITE
ORANGE
GROUND TO
FIREPLACE
CHASSIS
VALVE
INTERMITTENT
IGNITION
PILOT IGNITOR
MODULE 3 VAC
I
S
ORANGE
WHITE
GROUND TO
FIREPLACE
CHASSIS
WIRES
(TO BROWN)
VALVE
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents