Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces
Approved Vent Components
These fireplaces are designed, tested and listed for operation and installation with the following vent
components only:
Secure Vent
Secure Flex
Z-FLEX
Canada Limited.
Use only the correct size venting (4 1/2" inner and 7 1/2" outer).
These approved vent system components are labeled for identification. DO NOT use any other manufacturer's vent
components with these fireplaces.
Codes and Standards
These fireplaces comply with National Safety Standards and are tested and listed by PFS (Report No. F14-108) to
ANSI Z21.88 (in Canada, CSA-2.33), and CAN/CGA-2.17-M91 (CSA P4.1) in both USA and Canada, as vented gas
fireplace heaters.
These fireplaces are listed for installation in bedrooms, aftermarket mobile homes, and manufactured homes.
The installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54—latest edition (In Canada, the current CAN/CGA-B149.1 installation code).
The fireplace, when installed, must be electrically grounded and wired in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70—latest edition, or the Canadian Electrical
Code, CSA C22.1—latest edition.
BTU Input
Table 1: Input Rate, Gas Valves
Models
Table 2: Thermal Efficiency (%)
* AFUE is a measurement of the US Department of Energy
** P4 (EnerGuide) is a measurement of the Canadian Office of Energy Efficiency.
Gas Pressure
Table 3: Inlet Gas Supply Pressure
Table 4: Manifold Gas Supply Pressure
The control valves have a 3/8" (10 mm) NPT thread inlet and outlet side of the valve (Figure 1).
Direct-Vent System Components,
®
Flexible Vent Components, and
®
Model GA Venting Systems listed to UL1777 and ULCS635 manufactured by Flexmaster
®
Natural Gas
42"
54"
Model
42"
54"
Fuel
Natural Gas
Propane
Natural Gas
Propane
Input Rate (BTU/HR)
22,000
30,000
Natural Gas
AFUE *
P4 **
66.7
54.2
71.9
63.2
Minimum
5" WC / (1.25 kPa)
11.0" WC / (2.74 kPa)
3.5" WC / (0.87 kPa)
10.0" WC / (2.49 kPa)
Propane (field converted)
20,000
30,000
Propane
AFUE *
69.6
72.1
Maximum
10.5" WC / (2.61 kPa)
13.0" WC / (3.23 kPa)
Installation
900079-02 05/2015
P4 **
59.4
65.5
9