MAINTENANCE SCHEDULE
See the tables below for detailed information about required maintenance, both regular and annual.
Table 31: Maintenance Performed Annually—Before the Burning Season
Maintenance Task
Inspecting/Cleaning Burner, Panels, and
Controls
Checking Flame Patterns and
Flame Height
Inspecting/Cleaning Pilot and Burner
Checking Vent System
Fireplace Inspection
Replacing Batteries
Table 32: Maintenance Performed Periodically—After the Burning Season
Maintenance Task
Cleaning Firebox Interior
Check Flame Patterns and Flame Height
Checking Vent System
Cleaning Glass Door
Performed By
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Qualified Service Technician
Homeowner/Qualified Services Technician
Performed By
Homeowner
Homeowner
Homeowner
Homeowner
Procedure
Inspect valve and ensure it is properly
operating. Check piping for leaks. Vacuum
the control compartment and burner area.
Verify the flame pattern and height displayed
by the fireplace (Figure 38). Flames must not
touch the or fireplace walls or ceiling.
Remove any surface build-up on pilot and
burner assembly. Wipe the pilot nozzles,
igniter/flame rod and hood. Ensure the pilot
flame engulfs the flame sensor.
Remove baffle, inspect the vent system at
the top and at the base (within the firebox)
for signs of blockage or obstruction. Look
for any signs of dislocation of the vent
components.
Perform the appropriate fireplace inspection
procedure detailed in this manual
(Page 38).
For electronic gas valve models:
Replace the batteries in the battery holder.
Procedure
Carefully remove glass media (Page 60).
Vacuum out interior of the firebox. Clean
firebox walls. Replace removed items as
detailed in this manual.
Verify the flame pattern and height displayed
by the fireplace (Figure 38).
Inspect the vent system at the top and at
the base (within the firebox) for signs of
blockage or obstruction. Look for any signs
of dislocation of the vent components.
Clean as necessary following the directions
provided in this manual (Page 59). Do not
touch or attempt to clean the glass while hot.
Operation
900079-02 05/2015