RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
OTL Report No. 116-F-17-4
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS

DIRECT VENT

DT-400 AND DR-400
33" DIRECT-VENT GAS FIREPLACE HEATERS
P/N 725,023M REV. J 11/2004
MODELS
M
l i
v i l
M
o
e d
D
T
4 -
0 0
C
D
T
4 -
0 0
C
D
R
4 -
0 0
C
D
R
4 -
0 0
C
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où
vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifié installeur, agence de service ou le fournisseur
de gaz.
t l o
E
e l
r t c
n o
c i
s l
M
o
e d
s l
M
N
D
T
4 -
0 0
C
E
N
M
P
D
T
4 -
0 0
C
E
P
M
N
D
R
4 -
0 0
C
E
N
M
P
D
R
4 -
0 0
C
E
P
1

Advertisement

Table of Contents
loading

Summary of Contents for Superior DT-400

  • Page 1: Direct Vent

    HOMEOWNER'S CARE AND OPERATION INSTRUCTIONS DIRECT VENT DT-400 AND DR-400 33" DIRECT-VENT GAS FIREPLACE HEATERS P/N 725,023M REV. J 11/2004 MODELS v i l t l o r t c RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉ...
  • Page 2: Table Of Contents

    GENERAL INFORMATION Note: Installation and repair should be per- In selecting this SUPERIOR Direct-Vent Gas Appliance you have chosen the finest and formed by a qualified service person. The most dependable fireplace to be found anywhere. A beautiful, prestigious, alternative to appliance should be inspected annually by a a wood burning fireplace.
  • Page 3: Operation/Care Of Your Appliance

    Ne pas se servir de cet appareil s'il a été plongé Appliances with electronic systems will be fit- WARNING: CHILDREN AND ADULTS ted with the electronic valve shown in Figure 3 . dans l'eau, complètement ou en partie. Appeler SHOULD BE ALERTED TO THE HAZARDS un technicien qualifié...
  • Page 4: Variable Flame Adjustment (Millivolt)

    If your electronic appliance is not equipped Variable Flame Height Adjustment Inlet Pressure Port with a wall switch or remote control, the main burner must be turned off and on with the gas Manifold Pressure Port control switch. Toggle the switch from ON to OFF to operate the main burner .
  • Page 5: Maintenance Schedule

    Maintenance Schedule Annually (Before the onset of the Burning Season) Maintenance Task Accomplishing Person Procedure Inspect valve and ensure it is properly operat- Inspecting/Cleaning Burner, Logs Qualified Service Technician ing. Check piping for leaks. Vacuum the and Controls control compartment, fireplace logs and burner area.
  • Page 6: Front Glass Enclosure Panel, Removal And Installation

    Front Glass Enclosure Panel, Removal Refer to Figure 5 and remove the front glass Flame Appearance and Sooting enclosure panel as follows: and Installation. Proper flame appearance is a matter of taste. 1. Remove the top louver or radiant panel. Generally most people prefer the warm glow of a WARNING: NEVER OPERATE THE AP- yellow to orange flame.
  • Page 7: Log Placement

    Log Placement 3. Insert the alignment hole of the left twig over Allow the burner to operate for at least 15 the front log's left pin. Rotate the left twig until it minutes. Observe the flame continuously. If it just touches the edge of the ember bed bracket. appears weak or sooty as previously described, WARNING: LOGS GET VERY HOT AND adjust the air shutter by pushing or pulling on...
  • Page 8: Millivolt Appliance Checkout

    With proper care and maintenance, your ap- SIT and Honeywell Millivolt Appliance Checkout MILLIVOLT HONEYWELL pliance will provide many years of enjoy- Thermocouple The pilot flame should be steady, not lifting or ment. If you should experience any problem, Ignitor Rod floating.
  • Page 9: Warranty

    Electronic Wiring Diagram (Honeywell) Electronic Wiring Diagram (Honeywell) SIT And Honeywell Millivolt Wiring Diagram Showing the Blower Wiring for the Optional Showing the Blower Wiring for the Optional If any of the original wire as supplied must be replaced, FBK-100 and FBK-200 Kits FBK-250 Kits it must be replaced with Type AWM105 C –...
  • Page 10 ACCESSORY COMPONENTS CONTINUED Remote Control System (Standard) H0249 Arch Door Kits Remote Control System (Deluxe) H0251 RCL-T Standard Remote Control System Brass Finish 99L56 ADK-4B Brushed Stainless Finish 99L57 ADK-4BS (Model RCL) Deluxe Remote Control System (Model RCL-T) Arch Door Kits The Model RCL (Standard) Remote Control System, features a simplistic on/off control The Model RCL-T (Deluxe) Remote Control...
  • Page 11 ACCESSORY COMPONENTS CONTINUED Square Log Rack 99L59 DLR-4 Brass Finish Hood Kit 99L64 HK-4B Decorative Log Rack Brushed Stainless Finish Hood Kit 99L65 HK-4BS The decorative log rack provides the look of a Hood Kits wrought iron log rack. The rack installs easily in front of the log set with two screws.
  • Page 12: Lighting

    LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lighted with a piezo •...
  • Page 13 INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT : SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A.
  • Page 14 LIGHTING INSTRUCTIONS — ELECTRONIC FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions •...
  • Page 15 INSTRUCTIONS D’ALLUMAGE — ELECTRONIC POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE AVERTISSEMENT: SI VOUS NE SUIVEZ PAS CES INSTRUCTIONS À LA LETTRE, IL POURRAIT S’EN SUIVRE UN INCENDIE OU UNE EXPLOSION CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU MÊME DES PERTES DE VIE. A.
  • Page 16: Troubleshooting The Millivolt Gas Control System

    TROUBLESHOOTING THE MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas supply inlet) is in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. POSSIBLE CAUSES SYMPTOM CORRECTIVE ACTION...
  • Page 17: Troubleshooting The Electronic Ignition System

    TROUBLESHOOTING THE ELECTRONIC IGNITION SYSTEM ote: Before troubleshooting, be sure that the appliance main line gas shut-off valve, the gas control valve and the wall switch are in the “ON” position. Important: Valve system troubleshooting should only be accomplished by a qualified service technician. SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION...
  • Page 18: Replacement Parts List

    REPLACEMENT PARTS LIST Natural Propane DESCRIPTION Part No. Qty. Part No. Qty. Gas Fireplace Assembly – – – – Hood LB-91941FZ LB-91941FZ Louver LB-92400F LB-92400F Louver, (Base) LB-92402F LB-92402F Enclosure, Glass Front (Complete) LB-92534H LB-92534H Nameplate (Brand) 56L9301 56L9301 Latch 69L2101 69L2101 Catch, Door, Magnetic...
  • Page 19 REPLACEMENT PARTS NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
  • Page 20 The manufacturer reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information. Printed in U.S.A. © 2002 by LENNOX HEARTH PRODUCTS 1110 West Taft Avenue P/N 725,023M REV.

Table of Contents