Superior DRL3042TEN Installation And Operation Instructions Manual page 20

Drl3000 linear direct-vent gas fireplaces
Table of Contents

Advertisement

Innovative Hearth Products
Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces
If propane is used, be aware that with a tank that is too small (i.e., under 100 lbs, if this is the only gas
appliance in the dwelling—see NPFA 58), there may be a loss of pressure. This can result in insufficient
fuel delivery that can cause sooting, delayed ignition, or other malfunctions. Any damage resulting from an
improper installation is not covered by the limited warranty.
Rough in the Electrical Supply, if Needed
4.
1. As necessary, rough in the fireplace electrical supply per NEC and local codes.
Place the Fireplace in the Framing and Secure
5.
1. Secure the fireplace to the side framing members using the unit's nailing flanges —one top and bottom on each
NOTE: Nailing flanges, combustible members, and screw heads in areas directly adjacent to the nailing flanges are
EXEMPT from the 1/2" clearance to combustible requirements for the firebox outer wrapper. Combustible framing
may be in direct contact with the nailing flanges and may be located within 1/2" of screw heads and the firebox
wrapper in areas adjacent to the nailing flanges.
VENT SYSTEM PREPARATION
Select a Horizontal or Vertical Vent System
6.
1. With the fireplace secured in the framing, determine the vent route and identify the exterior termination location.
NOTE: This fireplace must be vented directly to the outside.
The vent system may not service multiple appliances, and must never be connected to a
flue serving a separate solid fuel burning appliance.
NOTE: The vent pipe is tested to be run inside an enclosed wall (such as a chase). There is no requirement for
inspection openings in the enclosing wall at any of the joints in the vent pipe.
Install the Vent Restrictor (if necessary)
7.
1. Use the vent run descriptions in Figure 14 to determine if a vent restrictor is necessary.
2. If necessary, assemble the vent restrictor and wings as detailed in Figure 14 and Figure 16.
3. If necessary, install the appropriate vent restrictor with the flaps facing up (Figure 15). The vent restrictor is held in
20
Check with the local building official for local code requirements (e.g., Are below grade penetrations of the gas
line allowed?, etc).
side of the fireplace front. Use 8d nails or the equivalent.
The following sections describe vertical (roof) and horizontal (exterior wall) vent applications. Use only approved
vent components (Page 9 and Page 46).
place by friction. The vent restrictor must not be visible inside the firebox.
NOTE: If the baffle and back panel are installed, remove them before installing the vent restrictor.
NOTE: The vent restrictor is shipped in the firebox.
CAUTION
WARNING
Installation
900079-02 05/2015

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drl3054tenDrl3054tepDrl3042tep

Table of Contents