Superior DRI3030TEN Installation And Operation Manual

Direct-vent fireplace insert
Hide thumbs Also See for DRI3030TEN:
Table of Contents

Advertisement

P/N 900125-01 REV. A 01/2015
A French manual is available upon request. Order
P/N 900185-01.
Ce manuel d'installation est disponible en
francais, s implement en faire la demande.
Numéro de la pièce 900185-01.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements locaux
le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque signalétique. Cet
appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
Direct-Vent
Fireplace Insert
C
US
Report # 14-192
This fireplace insert is factory equipped for 40,000 BTU input and can be converted to
33,000 using a smaller orifice (provided in optional orifice kit P/N H5924 for Natural Gas
or P/N H5925 for Propane Gas).

INSTALLATION AND OPERATION

MODELS
DRI3030TEN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pour-
rait d'entraîner des blessures graves, la mort ou des
dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié ou
par le fournisseur de gaz.
P900125-01
DRI2530TEN

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRI3030TEN

  • Page 1: Installation And Operation

    Ce manuel d’installation est disponible en francais, s implement en faire la demande. Numéro de la pièce 900185-01. DRI3030TEN DRI2530TEN This fireplace insert is factory equipped for 40,000 BTU input and can be converted to 33,000 using a smaller orifice (provided in optional orifice kit P/N H5924 for Natural Gas or P/N H5925 for Propane Gas).
  • Page 2 SAFETY AND YOUR FIREPLACE INSERT See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier* designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3: Safety And Your Fireplace Insert

    La sécurité et votre Safety and Your Seguridad y su poêle encastrable Fireplace Insert chimenea All parts of your IHP Toutes les parties de votre ¡Todas las partes de la poêle encastrable IHP fireplace insert get chimenea IHP se ponen deviennent EXTRÊMEMENT EXTREMELY HOT! MUY CALIENTES!
  • Page 4: Table Of Contents

    CONGRATULATIONS! Zero Clearance Fireplace Installation ......17 Firebox Panel Kit (required accessory) ....17-18 When you purchased your new gas fireplace insert, you joined Log Set Installation .......... 17-18 the ranks of thousands of individuals whose answer to their home Surround Panels Installation (required accessory) ..
  • Page 5: Important Safety Information

    IMPORTANT SAFETY INFORMATION Important Safety Informa- Información importante de L’information de sûreté tion seguridad importante 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Homeowner - Attaching Safety In Operation Warnings

    HOMEOWNER’S INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS ATTACHING SAFETY IN OPERATION WARNINGS COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD APPOSITION DES MISES EN GARDE RELATIVES EN OPERACIóN à LA SéCURITé D’UTILISATION Your appliance has been furnished with safety instruc- tion labels that are to be affixed to the operation and Su artefacto incluye etiquetas de instrucciones de Votre appareil a été...
  • Page 7: Installer - Attaching Safety In Operation Warnings

    INSTALLER INSTRUCTIONS - ATTACHING SAFETY IN OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. ATTACHING SAFETY IN OPERATION WARNINGS APPOSITION DES MISES EN GARDE RELATIVES COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD It is required that the set of safety instruction labels...
  • Page 8: Appliance Installation, Service, And Maintenance Notices

    Appliance Installation, Service, and If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Maintenance Notices Si l'écran est endommagé, il doit être remplacé par celui fournit par le fabricant de cet appareil. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
  • Page 9: Important Safety And Warning Information

     Plated surfaces must be cleaned with glass cleaner and a clean IMPORTANT SAFETY AND WARNING soft cloth before firing the first time or fingerprints will remain INFORMATION permanently. NEVER use brass polish to clean plated surfaces, this will remove the plating!!!  C AUTION: Hot while in operation.
  • Page 10: Orifice Size/Altitude Adjustment

    IMPORTANT: When installing these appliances into a factory ORIFICE SIZE/ALTITUDE ADJUSTMENT built fireplace or heat-form, the air flow within and around the fireplace shall not be altered by the installation of the insert For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice (i.e.
  • Page 11: Codes And Approvals

    CODES AND APPROVALS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Certification These appliances are approved for installation in the US state of Mas- sachusetts if the following additional requirements are met: Gas appliances must be tested and certified by a nationally recognized • Install this appliance in accordance with Massachusetts Rules and testing and certification laboratory to ANSI (American National Standard Regulations 248 C.M.R.
  • Page 12: Pre-Installation

    This appliance comes from the factory equipped to burn natural gas at a specified elevation. Only IHP conversion kits can be used to convert from NG to LP or LP to NG. Contact your IHP dealer for details. RATINGS DRI3030TEN-40 / DRI2530TEN-40 DRI3030TEN-33 / DRI2530TEN-33 NATURAL GAS LP GAS...
  • Page 13: Insert And Fireplace Dimensions

    31-1/4" 31-1/8 (794mm) O.D. = 2-15/16" (75mm) 15-7/8" 15-7/8 13-3/8" (403mm) 13-3/8 (340mm) Top View 15-7/8" 15-7/8 (403mm) 19-3/8" 19-3/8 (492mm) Right Side View Front View Left Side View Figure 2 - Insert Dimensions Minimum Fireplace Opening 31-1/2" (800mm) Front Opening Width 19-1/2”...
  • Page 14: Clearances To Combustibles

    927mm Facing and Mantel Clearances Please note that the DRI3030TEN-33 and DRI2530TEN-33 mantel clear- ances are 4" less than the DRI3030TEN-40 and DRI2530TEN-40 mantel clearances as shown in Figure 4A - DRI3030TEN-40 and DRI2530TEN-40 and Figure 4B - DRI3030TEN-33 DRI2530TEN-33.
  • Page 15: Fan Control Module Switch (Rdv 33/40 Tcc Models Only)

    FAN CONTROL MODULE SWITCH INSTALLATION DRI3030TEN-33 and DRI3030TEN-40 Models Only Venting Installation Before installation, verify the power switch on the Fan Control Module is in the ON position (as shown in Figure 6). Your IHP appliance must be vented to the outside in accordance with the current edition of the National Fuel Gas Code ANSI-Z223.1 (In Canada, the...
  • Page 16 Vertical Venting The existing fireplace chimneys The vent pipes must be connected to the proper collars on the unit and may take various contours the exhaust vent pipe must be connected to the termination cap or the which the flexible liners will unit will not operate.
  • Page 17: Zero Clearance Fireplace Installation

    5. Reinstall burner by completing Step 3 in reverse. 6. Reinstall log rack by completing Step 2 in reverse. 7. The foil sticker supplied, stating DRI3030TEN-33 or DRI2530TEN-33, Rear Log Log Rack will need to be affixed below the model name on the serial number label (located in the control compartment).
  • Page 18: Surround Panels Installation (Required Accessory)

    Top Log Figure 13 Ports Surround Installation The fireplace insert surround panels are made of heavy gage steel for durability and, if desired, for the ease of making an inside fit in the fire- Figure 10 Side Firebox Panels place. See Packaging List for available sizes. 1.
  • Page 19: Operating Options

    - DRI2530TEN Models Only Operating Options OPTION 1 Burner ON/OFF Switch Installation: Surround The burner ON/OFF switch on your gas appliance is used to turn the burner Panel on and off. This switch can be installed in the hole in the right side of the top surround panel (see Option 1) or in the hole in the control panel in the control compartment (see Option 2).
  • Page 20: Gas Line Installation

    Cover the tap with the line from DRI3030TEN Models a manometer and check the pressure. Close the tap gently but securely Stepper Motor Green Wire after completing the check.
  • Page 21: Air Shutter Adjustment

    BL OW ER OF F DRI2530TEN Battery Holder See Shutter Adjustment Figure 19a Detail (Figure 19b) BU RN ER DRI3030TEN TO TA L AU TO CO MF OR CO NT RO PIL OT 5/32” Air Shutter Setscrew Battery Holder Ensure Positive and Negative...
  • Page 22: Installer - Attaching Safety In Operation Warnings

    INSTALLER INSTRUCTIONS - ATTACH SAFETY-IN- A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. OPERATION WARNING LABELS B. BEFORE OPERATING smell all around the appliance area for gas. Be sure It is required that the set of safety instruction labels that have to smell next to the floor because some gas is heavier than air and will been furnished with the appliance be affixed to the operation...
  • Page 23: Intermittent/Standing Pilot Mode

    Electronic Gas Control Valve SIT Proflame, Stepper BU RN ER TO TA L C O M FO C O N TR AU TO PI LO T Unit-Mounted Controls Figure 21B - DRI3030TEN Models NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 24: Operation - Model Rdv33/40 Tcc Only

    OPERATION - DRI3030TEN Model Only Receiver Remote Control System REMOTE OFF The Remote and Receiver allows you to command the functions of your appliance from the comfort of your chair and is configured to control the On/Off primary burner operation, its flame levels (through six levels) and provides On/Off and Smart thermostatic control of the appliance.
  • Page 25 OPERATION - DRI3030TEN Model Only Child Safety Lock-Out Transmission Low Battery Alarm Temperature Indicator Display Thermostat With the system in the “OFF” position, press the Thermostat Key and Room Temperature Off/On/Smart the Mode Key at the same time (see Figure 23). Look at the LCD screen...
  • Page 26: Flame Color And Behavior

    3. Once the blower turns on, turn the knob (DRI2530TEN) or adjust Adjust the primary air shutter(s) as required. Check for proper main the remote control (DRI3030TEN) to the desired speed. No further burner operation at both high and low flame.
  • Page 27: Wiring Diagrams

    120 V AC POWER OUTLET ROOM AIR BLOWER AC/DC ADAPTER BURNER PILOT CONTROL NOTE: SWITCH CONDITIONS BOARD GIVEN AT ROOM TEMPERATURE N/C = NORMALLY CLOSED 3-BLK N/O = NORMALLY OPEN = FEMALE DISCONNECT 9 - YLW = MALE DISCONNECT VALVE 8 - GRN 2 - RED = STUD CONNECTION...
  • Page 28 N/C = NORMALLY CLOSED N/O = NORMALLY OPEN = FEMALE DISCONNECT Figure 28C - Electronic Control Schematic - Model DRI3030TEN = MALE DISCONNECT = STUD CONNECTION CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
  • Page 29: Maintenance And Servicing

    o Check that the area around the insert is kept clear and is free of MAINTENANCE AND SERVICING combustible materials, gasoline and other flammable vapors and liquids. WARNING 2. The viewing glass should be cleaned periodically (see Glass Main- tenance). Turn off gas and electrical power to the fireplace and allow it to cool before cleaning or servicing the appliance.
  • Page 30: Door Removal

    Glass Door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstalling the glass door frame. •...
  • Page 31: Fuel Conversion

    Repair: If the glass is broken in the glass door, the entire door (metal frame, gasket and glass) should be replaced as a unit. This replacement See Detail B glass door is available from your IHP dealer. Do not use substitute parts or materials.
  • Page 32: Replacing A Damaged Barrier

    Replacing A Damaged Barrier • If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. • For use with barrier Part No. J7510 (Contemporary Facade). Follow installation instructions. Removing The Damaged Barrier Contemporary Facade (see Figure 33) 1.
  • Page 33: Troubleshooting

    Check/replace back-up batteries (see Battery Backup on Page 21). ing power. Check building circuit breakers to ensure power is on to the appliance. DRI3030TEN Models: Check Fan Control Module power switch to ensure power is on (see Figure 6 on Page 15). The main burner does Gas is not reaching the Check the gas supply and gas shutoff valves.
  • Page 34: Replacement Parts

    H8457 Gas Conversion Kit, Manual Hi/Lo Regulator, NG H8505 DRI3030TEN Control Panel to LP H8482 Heat Shield, Fan Control Module - For DRI3030TEN Models Only H3080 Control Valve Knob Extension, Manual Hi/Lo - SIT H8483 Blower Snap Switch, 160°-20°F H5752...
  • Page 35: Replacement Parts

    REPLACEMENT PARTS - DRI3030TEN AND DRI2530TEN Facade NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 36: Accessories

    ACCESSORIES - DRI3030TEN AND DRI2530TEN DRI3030TEN-33 DRI2530TEN-33 Product Reference Information Gas Conversion Kits Cat. No. Description Ship. Ship. Weight Volume F1788 DRI3030TEN 144 lb. 16.9 cu. ft. F1787 DRI2530TEN 144 lb. 16.9 cu. ft. Cat. No. Model Description H8456 RDV-CK-HILO-LP to NG...
  • Page 37 Surround Trim Kits Cat. No. Model Description H5143 GFT2941-B Trim/Black 29" x 41" Contemporary Facade Kits With Barrier H5145 GFT2948-B Trim/Black 29" x 48" H5144 GFT3341-B Trim/Black 33" x 41" H5146 GFT3348-B Trim/Black 33" x 48" 75036 GFT2941-G Trim/Gold 29" x 41" Cat.
  • Page 38: Insert Labels

    SAFETY / LISTING LABEL - DRI2530TEN SERIAL SERIAL Le numéro de série est indiqué dans la MODÈLE DRI2530TEN MODEL DRI2530TEN section anglophone de cette étiquette FABRIQUÉ PAR: MANUFACTURED BY: INNOVATIVE HEARTH PRODUCTS INNOVATIVE HEARTH PRODUCTS 1502 14TH ST NW Rapport nº 14-192 1502 14TH ST NW Report No.
  • Page 39 AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22.1. WARNING: IF UNIT IS CONVERTED TO A DRI3030TEN-40 FROM A DRI3030TEN-33 ENSURE THAT THE SI LE MODÈLE DRI3030TEN-33 EST CONVERTI COMME MODÈLE DRI3030TEN-40, ASSUREZ VOUS QUE CLEARANCES TO COMBUSTIBLES ARE CORRECT FOR DRI3030TEN-40.
  • Page 40 LIGHTING LABEL POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque property damage, personal injury or loss of life.
  • Page 41: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 42: Product Reference Information

    PRODUCT REFERENCE INFORMATION When ordering repair parts, always give the following information: 1. The model number of the appliance. We recommend that you record the following important information 2. The serial number of the appliance. about your appliance. Please contact your IHP dealer for any questions 3.

This manual is also suitable for:

Dri2530ten