Error Codes - Lincoln Electric RED-D-ARC FX450 Operator's Manual

Lincoln electric welder user manual
Table of Contents

Advertisement

E-3
USING THE STATUS LED TO TROUBLESHOOT SYSTEM PROBLEMS
Errors are displayed on the user interface. In addition, there are status lights on the control pc board and the
switch pc board that contain error sequences.
Included in this section is information about the Status Lights and some basic troubleshooting charts for both
machine and weld performance.
The status lights on the main control board and the switch pc board are dual-color LEDʼs. Normal operation for
each is steady green.
Error
Description
Code#
31
Primary Over Current
711
Capacitor over-or-under volt-
age.
712
Communication error between
P.C. boards or P.C. board
fatal.
713
Input Power Misconnect
Supply Voltage is too high.
714
Input Power Misconnect
Supply Voltage is too low.
715
Supply Voltage to the switch
Printed Circuit Board is too
low.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
Error Codes for the FX450
Check the input power (voltage and fre-
quency). Verify the primary reconnect is
properly configured for the input voltage.
If condition persists contact an authorized
Field Service Shop.
Check input power (voltage and frequency)
while welding. Verify the primary reconnect
is properly configured for the input voltage.
Re-trigger to recover from error.
If condition persists contact an authorized
Field Service Shop.
Verify the primary reconnect is properly
configured for the input voltage.
If condition persists contact an authorized
Field Service Shop.
If condition persists contact an authorized
Field Service Shop.
FX450 (RED-D-ARC)
Corrective Action
CAUTION
Machine needs to be turned
off and back on to reset.
Machine needs to be turned
off and back on to reset.
Weld Terminals Remote:
Re-trigger to recover from
error.
Weld
Terminals
Local:
Toggle Remote/Local Switch
to recover from error.
Machine needs to be turned
off and back on to reset.
Machine needs to be turned
off and back on to reset.