Error Codes - Lincoln Electric SPIRIT II 275 Technical Manual

Plasma cutting system with fineline high definition technology
Hide thumbs Also See for SPIRIT II 275:
Table of Contents

Advertisement

Spirit II User's Manual

Error Codes

The following is a comprehensive list of error codes for the Spirit system. When the system
uses a Manual Gas Console, only the numeric error code is displayed. When an Automatic
Gas Console is used, the text description is also displayed.
Code
Short Description
10121
ASC Door
10138
Stop Pressed (Off Button)
10140
Phase R
10150
Phase Y
10160
Phase B
10161
CON1
10170
Coolant Level
10180
Coolant Flow Low
10190
Coolant Flow High
10220
Coolant Temperature High
10290
GC Quiet
10300
PC Quiet
10320
FCC Invalid
10330
PAC Invalid
10340
AH IHS Timeout
10350
PAT Not Established
10360
TAC Not Established
10370
Current Unbalanced
10380
TAC Lost 1
10390
TAC Lost 2
10400
TAC Lost 3
10410
TAC Lost 4
10420
FCC Unreached
10430
Output Over Current
10432
Output Over Current TZ
10440
Output Over Voltage
10450
Start Premature Removal
10461
Chopper1 Temp
10462
Chopper2 Temp
10463
Chopper3 Temp
This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to
non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.
Section 6: Maintenance &Troubleshooting
Power Supply
Long Description
ASC Door is open
OFF Button on Plasma Console or Manual Gas
Console is pressed.
Transformer Secondary phase voltage is low
Transformer Secondary phase voltage is low
Transformer Secondary phase voltage is low
Main Contactor failed to open
Coolant Level is low
Coolant flow is low
Coolant flow is high
The coolant temperature is high
Lost CAN communication with Gas Console
Lost CAN communication with Plasma Console
Using default current, remove start
Pilot Arc Current invalid
Arc Hold for Initial Height Sense has timed out
Pilot Arc Current not established within 2 seconds
Transferred Arc Current not established within 2
seconds
Current is not balanced between chopper
assemblies (275A and 400A systems)
Transferred Arc lost during TAC hold time
Transferred Arc lost during Upslope
Transferred Arc lost during Cutting
Transferred Arc lost during Downslope
Did not achieve final cut current
Chopper has exceeded its maximum rated current
Instantaneous Over Current detected
Maximum Cutting Voltage has been exceeded.
Start Signal removed prior to completion of upslope
Chopper 1 maximum operating temperature
exceeded
Chopper 2 maximum operating temperature
exceeded
Chopper 3 maximum operating temperature
exceeded
6-7