MUFFLER RELOCATION

WARNING
Shut off the machine and allow the muffler to cool
before touching the muffler.
The RANGER 10-LX is shipped with the exhaust
directed toward the rear. It can be changed to the right
side by loosening the clamp that holds the exhaust
deflector in place and rotating the deflector to the
desired direction.

SPARK ARRESTER

Diesel engine mufflers may emit sparks when the
engine is running. Some federal, state, or local laws
require spark arresters in locations where unarrested
sparks could present a fire hazard.
INSTALLATION
FIGURE A.1 - RANGER 10-LX OUTPUT CONNECTIONS
4
3
RANGER 10-LX
1. 115/230 VOLT, 50 AMP RECEPTACLE
2. 115 VOLT, 20 AMP RECEPTACLES (2)
3. WELD OUTPUT TERMINALS (2)
4. GROUND STUD (LOCATION)
5. CIRCUIT BREAKERS (CSA machines only)
Standard mufflers and deflectors (like the ones includ-
ed with the RANGER 10-LX) do not act as spark
arresters. When local laws require it, a spark arrester
must be installed on the machine and properly main-
tained. An optional spark arrester kit (K903-1) is avail-
able for your RANGER 10-LX. See the Accessories
section of this manual for more information.
CAUTION
An incorrect spark arrester may lead to damage to the
engine or reduce performance.
ELECTRICAL OUTPUT
CONNECTIONS
See Figure A.1 for the location of the 115 and 230 volt
receptacles, weld output terminals, circuit breakers
and ground stud.