A-5
OUTBACK® 185 OUTPUT CONNECTIONS
9
10
1. CURRENT CONTROL DIAL
2. WELD OUTPUT TERMINALS (2)
3. GROUND STUD
4. CIRCUIT BREAKERS (2) - 20 AMP
5. CIRCUIT BREAKER 30 Amp
6. RECEPTACLE - 240 VOLT, 50 AMP

ELECTRICAL OUTPUT CONNECTIONS

See Figure A.1 for the location of the current control
dial, weld output terminals, ground stud, circuit break-
ers, 240 and 120 volt receptacles.
WELDING CABLE CONNECTIONS
Cable Size and Length
Be sure to use welding cables that are large enough.
The correct size and length becomes especially impor-
tant when you are welding at a distance from the welder.
Table A.1 lists recommended cable sizes and lengths for
rated current and duty cycle. Length refers to the dis-
tance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.
INSTALLATION
1
8
7
3
2
FIGURE A.1
7. DUPLEX RECEPTACLE (2)- 120 VOLT, 20 AMP
8. HOURMETER
9. ENGINE SWITCH
10. CHOKE
50-100 ft (15-30 m)
100-150 ft (30-46 m)
150-200 ft (46-61 m)
200-250 ft (61-76m)
OUTBACK® 185
4
TABLE A.1
RECOMMENDED WELDING CABLE
SIZE AND LENGTH
TOTAL COMBINED LENGTH OF
ELECTRODE AND WORK CABLES
Cable
Length
0-50 ft (0-15m)
A-5
5
6
125 Amps
30% Duty Cycle
6 AWG
5 AWG
3 AWG
2 AWG
1 AWG