See Figure A.1 for the location of the current control
dial, weld output terminals, ground stud, circuit break-
ers, 230 and 115 volt receptacles.

WELDING CABLE CONNECTIONS

Cable Size and Length

Be sure to use welding cables that are large enough.
The correct size and length becomes especially impor-
tant when you are welding at a distance from the
welder.
Table A.1 lists recommended cable sizes and lengths
for rated current and duty cycle. Length refers to the
distance from the welder to the work and back to the
welder. Cable diameters are increased for long cable
lengths to reduce voltage drops.
INSTALLATION
2
4. CIRCUIT BREAKERS (2) - 20 AMP (15 AMP CSA)
5. RECEPTACLE - 230 VOLT, 20 AMP (15 AMP CSA)
6. DUPLEX RECEPTACLE - 115 VOLT, 20 AMP (15 AMP CSA)
TOTAL COMBINED LENGTH OF ELECTRODE AND
Cable Length
0-50 feet (0-15 meters)
50-100 feet (15-30 meters)
100-150 feet (30-46 meters)
150-200 feet (46-61 meters)
200-250 feet (61-76 meters)
WELDANPOWER 125
1
3
4
TABLE A.1
RECOMMENDED WELDING CABLE
SIZE AND LENGTH
WORK CABLES
A-5
6
5
Cable Size for
125 amp/
30% Duty Cycle
6 AWG
5 AWG
3 AWG
2 AWG
1 AWG