6.10 OPTIONAL NZ64 BLOWER INSTALLATION

EN
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES AND WITH THE NATIONAL ELECTRIC CODE ANSI/NF NO. 70-CURRENT (IN THE
UNITED STATES), OR WITH THE CURRENT CSC22.1 CANADIAN ELECTRIC CODE (IN CANADA).
NOTE: Consideration should be made for blower location as the closer to the appliance the greater the
air fl ow noise will be. Blower may be installed on either side of the appliance.
Route a 120 Volt, 60Hz electrical supply (not supplied) from the electrical box on the side of the appliance to
the electrical box on the blower housing.
The appliance comes complete with a safety switch and a thermally activated switch.
Blower may be installed
on either side of the unit
A.
Remove the template.
B.
Position the blower to an inside or outside wall into
a framed opening 12
(267mm) high. (Outside wall not recommended in
colder climates as cold air may be drawn into the
house when the appliance is off.)
The blower housing should be installed onto a level
surface large enough to support the blower assembly.
Allow for fi nishing material when securing the blower
housing, as the grill mounts to the housing.
W415-1501 / 05.15.15
L2
Optional summer fan
switch (not supplied)
3
/
" (314mm) wide by 10
1
8
FOR COMPLETE INSTRUCTIONS,
SEE BLOWER KIT.
Blower housing may be
installed inside a home
that has sufficient air flow.
/
"
2
Blower housing may
be installed on an
outside wall to bring
in fresh air for hot air
circulation (not
recommended in
colder climates)
Housing must be
mounted
horizontally
L1
L
A L
E W
I D
T S
O U
G
I N
U S
H O
E R
O W
B L