Optional Nz64 Blower Installation - Napoleon High Country 6000 Series Installation And Operation Manual

Table of Contents

Advertisement

Available languages

Available languages

7.9

optional NZ64 blower installation

!
WARNING
All wiring should be done by a qualifi ed electrician and shall be in compliance with local codes and with the
National Electric Code ANSI/NF No. 70-Current (in the United States), or with the current CSC22.1 Canadian
Electric Code (in Canada).
note:
Consideration should be made for blower location as the closer to the appliance, the greater the air fl ow noise
will be. Blower may be installed on either side of the appliance.
Route a 120 Volt, 60Hz electrical supply (not supplied) from the electrical box on the side of the appliance to the
electrical box on the blower housing.
The appliance comes complete with a safety switch and a thermally activated switch.
Blower may be installed
on either side of the unit
A.
Remove the template.
B.
Position the blower to an inside or outside wall into
a framed opening 12
(267mm) high. (Outside wall not recommended in colder
climates as cold air may be drawn into the house when
the appliance is off.)
note:
The blower housing should be installed onto a level surface
large enough to support the blower assembly.
Allow for fi nishing material when securing the blower hous-
ing, as the grill mounts to the housing.
L2
Optional summer fan
switch (not supplied)
3
/
" (314mm) wide by 10
1
/
8
FOR COMPLETE INSTRUCTIONS,
SEE BLOWER KIT.
Blower housing may be
installed inside a home
that has sufficient air flow.
"
2
fi nishing
Blower housing may
be installed on an
outside wall to bring
in fresh air for hot air
circulation (not
recommended in
colder climates)
Housing must be
mounted
horizontally