OPTIONAL NZ64 BLOWER INSTALLATION

ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES AND WITH THE NATIONAL ELECTRIC CODE ANSI/NF NO. 70-CURRENT (IN THE
UNITED STATES), OR WITH THE CURRENT CSC22.1 CANADIAN ELECTRIC CODE (IN CANADA).
This appliance is supplied with two micro (pressure) switches (the blower on high draws 3.0 amps using
120V (approx. 360w) and a thermally activated switch.
Ensure that the pressure switch actuating arm protrudes through the
faceplate when installed and moves freely.
The blower will only operate when the doors are fully closed and the air control
is not set to it's "super low" burn rate.
BLOWER INSTALLATION
NOTE: Consideration should be made for blower location as the closer to
the appliance the greater the air fl ow noise will be.
A.
Position the blower to an inside or outside wall into a framed
opening 12
mended in colder climates as cold air may be drawn into the
house even when the blower is off.)
The blower housing should be installed onto a level surface large
enough to support the blower assembly. Allow for fi nishing mate-
rial when securing the blower housing, as the grille mounts to the
housing.
COLLAR INSTALLATION
B.
Determine which side of the appliance the blower is to be located
on. Remove and discard the cover plate and install the 6" collar.
Secure by reaching through the collar and bending the tabs.
Use sealant to ensure that the connection is air tight.
ELECTRICAL CONNECTION
C.
Remove the junction box covers on the appliance and the
blower.
Removing the junction box cover on the appliance exposes 4
black, labeled wires:
Two wires labelled "by-pass" - go to by-pass (summer) switch
(not supplied - overrides the thermally activated switch enabling
the user to run the blower without heat).
IMPORTANT: If the by-pass, (summer) switch is not desired,
terminate the wires by attaching wire nuts to by-pass (sum-
mer) switch wire leads separately (do not connect together).
One wire labelled "blower" - connects to KB-35 rheostat and then
KB-35 connects to white blower wire.
One wire labelled "L1" - connects to power (hot lead).
- Removing the junction box cover on the blower
exposes 3 coloured wires:
W415-0711 / B / 11.23.10
3
1
/
" wide by 10
/
" high. (Outside wall not recom-
2
8