Clearances; Insert Clearances; Mantel Clearances; Hearth Requirements - Vermont Castings 30ILDVNV Installation And Operating Instructions Manual

Ildv series direct vent gas fireplace insert
Table of Contents

Advertisement

30ILDV Series Gas Fireplace Insert

INSERT CLEARANCES

No combustibles (ie: drapes, doors) may be within, or
swing within 36" of the front of the insert.
Side Wall
10" (254 mm)
Minimum
Figure 3

Mantel Clearances

MANTEL CLEARANCES
NOTE: The combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
8
12"
(305 mm)
12" (305 mm)
Minimum
42" (1067 mm)
Minimum
FP1947
insert clearances
9/08
WARNING
The dimensions shown on Pages 8 and 9, Figures 3 and
4, are minimum clearances to maintain when installing
this heater. Follow these instructions carefully to ensure
safe installation. Failure to follow instructions exactly can
create a fire hazard.
12" (305 mm)
Maximum Depth
9"
(228 mm)

HEARTH REQUIREMENTS

The insert must be installed on a noncombustible hearth
extending a minimum of 12" from the fireplace opening
(local codes may require a larger hearth). The hearth must
also extend to both sides of the face (Refer to the table
on Page 7).

CLEARANCES

3/4" (19 mm)
Maximum Depth
Combustible Facing
NOTE: Side clearance to com-
bustibles is 10" (254 mm) from
opening whether it is side wall
or mantel legs.
FP1947
20306755