PRE-INSTALLATION INFORMATION
CLEARANCES TO COMBUSTIBLES
Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire
hazard.
The appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring. If installed on
carpet or vinyl flooring, the appliance shall be installed on a metal, wood or noncombustible material panel extending
full width and depth of the appliance.
Side Wall
72"
Maximum Depth
(1829 mm)
Minimum
6"
(152 mm)
Min.
Figure 4 -
Ceiling and Side Wall Clearances
FP2408
DVM MDV clearances
MANTEL CLEARANCES
NOTE: The combustible area above the facing must not protrude
more than 1/2" from the facing. If it does, it is considered a mantel
and must meet the mantel requirements listed in this manual.
WARNING
Never obstruct or modify the air inlet or outlet grilles
(louvers). This may create a fire hazard.
20306747
Combustible
Mantel
12"
(305 mm)
(305 mm)
Minimum
FP2408
DVM Series Direct Vent Gas Fireplace
WARNING
12"
10"
12"
10³⁄₄"
9¹⁄₂"
Top of Fireplace
12"
Opening
FP2410
8"
6"
4"
2¹⁄₂"
8¹⁄₄"
7"
6"
Side View
FP2409
Mantel clearance
1"
2¹⁄₂"
3"
5"
6"
FP2410
Figure 5 -
mantel leg clearance
Mantel Clearances
Stud
Header
Standoff
Insulation
Board
FP2409
Finish Wall
Combustible
Material Area
1¹⁄₂"
3¹⁄₂"
4¹⁄₂"
45°
9