Clearances; Insert Clearances; Mantel Clearances; Hearth Requirements - Vermont Castings ICFDV Series Installation And Operating Instructions Manual

Direct vent gas fireplace insert
Table of Contents

Advertisement

ICFDV30 Fireplace Insert

INSERT CLEARANCES

No combustibles (ie: drapes, doors) may be within, or swing within 36" of the front of the insert.
Side Wall
10" (254 mm)
Minimum
10" (254 mm)
Minimum
Figure 3 -

Mantel Clearances

FP2992
30ICFDV clearances
Figure 4 -
Mantel Clearances
MANTEL CLEARANCES
NOTE: The combustible area above the facing must
not protrude more than 3/4" (19 mm) from the facing.
If it does, it is considered a mantel and must meet the
mantel requirements listed in this manual.
8
12" (305 mm)
Maximum Depth
12"
(305 mm)
9"
(228 mm)
Finish Wall
12" (305 mm)
12"
(305 mm)
10"
(254 mm)
Fireplace insert opening
NOTE: Side clearance to combustibles is 10" (254 mm)
from opening whether it is side wall or mantel legs.
4"
(101 mm)
3/4" (19 mm)
Noncombustible material
is required up to 9" above
fireplace opening
9"
(229 mm)

HEARTH REQUIREMENTS

The insert must be installed on a noncombustible hearth
FP2965
extending a minimum of 10" (254 mm) from the fireplace
mantel clearance
opening (local codes may require a larger hearth). The
hearth must also extend to both sides of the face.

CLEARANCES