clearances tO cOMBustIBles
Follow these instructions carefully to
ensure safe installation. Failure to follow
instructions exactly can create a fire
hazard.
the appliance cannot be installed on a carpet,
tile or other combustible material other than
wood flooring. If installed on carpet or vinyl
flooring, the appliance shall be installed on
a metal, wood or noncombustible material
panel extending full width and depth of the
appliance.
54" Minimum
Ceiling
12" Max.
Depth
6" Min.
FP2421
Figure 4 -
Ceiling and Sidewall Clearances
FP2421
Mantel clearances
mantel clearances
nOte: The combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
8
2
/
" Max
1
2
Depth
12" Min.
From Opening
6" Min.
From Opening
5 "
Min. to Combustibles
Wall
12"
6"
2
1
/
"
12"
2
9"
6"
Top of Fireplace
Opening
side View
FP2422
mantel clearances
FP2423
1"
2 "
Side of Fire-
place Opening
top View
Figure 5 -
Mantel clearances
FP2423
mantel leg

clearances

Stud
Insulation
Board
Standoff
FP2422
1 "
3
"
4
"
3"
45°
5"
6"
78D0011