Olivetti FK-502 Service Manual page 97

Hide thumbs Also See for FK-502:
Table of Contents

Advertisement

7. SERVICE MODE
4. Use the key provided on the left side of the screen to select a menu to be set.
5. Select the item and change parameter setting by pressing the [ + ] key / [ - ] key.
6. Press the [END] key to return Service Mode screen.
Parameter
Display
Closed area Rx
Setting
Compulsory Memory RX ON / OFF
Reject Calls
Relay
Re-Transmission
Scan
Frame Erasure HP
Setting
Original Reading Mode
Default (B&W MFP only)
System
Fax Board Watchdog
Function
Fax BOOT Rewrite on
ISW
Error Code Display Time
Operation
RX or Print Stop
Setting
Report Auto Output
STOP
90
Set Value
ON / OFF
ON / OFF
ON / OFF
ON / OFF
5,10,15 [mm]
Custom Size/Normal
ON / OFF
ON / OFF
HOLD / 10 to 250 [sec]
(in steps of 10 sec)
Effective/Invalid
Effective/Invalid
Service Manual
Field Service Ver. 7.0 Jan. 2009
15LAF3E024DA
15LAF3E024DA
Factory-shipped
Reference
Default Setting
ON
Yes
ON
Yes
OFF
Yes
ON
Yes
ON
Yes
5 [mm]
Yes
Custom Size
Yes
ON
Yes
OFF
Yes
20 [sec]
Yes
Effective
Yes
Effective
Yes
Y104784-2