Toshiba e-STUDIO167 Service Manual page 225

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO167:
Table of Contents

Advertisement

7) Abnormality detection by the thermistors
The following table shows the conditions judging the fuser roller temperature abnormality and
detecting timing.
Checking
Priority
timing
On usual
1
Detecting 40°C
1
Detecting 100°C
1
2
Detecting warm-
1
ing-up tempera-
ture
2
During ready sta-
1
tus
2
During copying
1
2
*
The figures in the "priority" section denote the priority of error checking.
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
Temperature judged
Center
Side
thermistor
thermistor
230°C or above
-
230°C or above
-
40°C or below
-
40°C or below
100°C or below
-
100°C or below
40°C or below
150°C or above
150°C or above
40°C or below
Warming-up temp.
or below
-
Warming-up temp.
or below
40°C or below
150°C or above
150°C or above
40°C or below
-
150°C or above
40°C or below
150°C or above
150°C or above
40°C or below
-
150°C or above
40°C or below
-
40°C or below
40°C or below
-
40°C or below
-
13 - 11
Edge
thermistor
-
-
-
-
230°C or above
-
-
-
-
-
-
-
-
-
-
-
-
-
40°C or below
-
-
40°C or below
-
-
-
-
-
-
-
40°C or below
Error-
Error
judging
code
timing
On usual
C44
Specified
C41
time
Specified
C44
time
On usual
C43
Specified
C44
time
On usual
C43
On usual
C43
C44
On usual
C44
C45
e-STUDIO167/207/237
FUSER / EXIT UNIT
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio237E-studio207

Table of Contents