Toshiba e-STUDIO167 Service Manual page 191

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO167:
Table of Contents

Advertisement

[Q] Temperature/humidity sensor (S3)
(1)
Take off the left cover.
P.2-19 "[C] Left cover"
(2)
Disconnect 1 connector, remove 1 screw,
and then take off the temperature/humidity
sensor.
[R] Toner cartridge interface PC board (CTIF)
(1)
Take off the process unit.
P.11-17 "[N] Transfer unit"
(2)
Take off the inner tray.
P.2-18 "[B] Inner tray"
(3)
Disconnect 1 connector, remove 1 screw and
then take off the toner cartridge interface PC
board.
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
Temperature/
Humidity sensor
Fig. 11-40
Connector
Toner cartridge
interface PC board
Fig. 11-41