Process Of Detection Of Original Size - Toshiba e-STUDIO167 Service Manual

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO167:
Table of Contents

Advertisement

6.6.2

Process of detection of original size

1) When the equipment is in the original size detection mode, contact image sensor unit (CIS) is set at
its home position.
2) When the platen cover is opened, the sensors receive the light reflected from the original and if one
of the matrix conditions shown in 4) for original sizes are met, the size of the original is instantly
detected.
3) The output signal from each sensor is input to ASIC on the MAIN board to determine the size of the
original.
[ A4 Series ]
APS-R
APS-C
Reflection type
APS-3
photosensor
APS-2
APS-1
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
[ LT Series ]
+5VAPS
+5V
Reflection type
ASIC
photosensor
SG
MAIN board
Fig. 6-8
6 - 13
+5VAPS
+5V
APS-R
APS-C
ASIC
APS-3
APS-2
SG
MAIN board
e-STUDIO167/207/237
6
SCANNER

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-studio237E-studio207

Table of Contents