(4)
Lift up the CIS unit, disconnect 1 connector
on the bottom of the CIS unit, and then take
off the CIS unit.
Notes:
Take care not to contaminate the CIS unit
surface with fingerprints, dust or such.
Be sure to perform "05-310" with the
platen cover or the ADF/RADF closed
after replacing the CIS unit.
(5)
Release 2 latches each to take off 2 original
glass guides from the CIS unit.
[H] CIS case
(1)
Take off the CIS unit.
P.6-23 "[G] CIS unit (CIS)"
(2)
Remove 1 screw and take off the belt stop-
per.
Note:
When installing the belt stopper, install it so
that the protrusion of the stopper fits in the V-
groove on the inside of the CIS unit drive
belt-1.
e-STUDIO167/207/237
SCANNER
Original glass guide
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
6 - 24
CIS unit
Connector
Fig. 6-30
Fig. 6-31
Belt stopper
CIS unit
drive belt-1
Fig. 6-32