[K] Paper empty sensor (S7)
(1)
Take off the drawer.
(2)
Take off the damp heater unit or dummy
plate.
P.10-19 "[J] Damp heater unit (DH3) /
Dummy plate"
(3)
Disconnect 1 connector, remove 1 screw,
and take off the bracket of the paper empty
sensor.
(4)
Release 2 latches and take off the paper
empty sensor from the bracket.
e-STUDIO167/207/237
PAPER FEEDING SYSTEM
Connector
Bracket
© February 2007 TOSHIBA TEC CORPORATION All rights reserved
10 - 20
Bracket
Fig. 10-33
Paper empty sensor