Toshiba RAV-SP560AT-E Service Manual page 40

Split type
Hide thumbs Also See for RAV-SP560AT-E:
Table of Contents

Advertisement

RAV-SP800AT-E (A03-014)
Outer diameter of refrigerant pipe
Gas side ØA
Liquid side ØB
15.9mm
9.5mm
TS sensor
TD sensor
Accumulator
(1500cc)
Rotary compressor
(DA220A2F-20L)
Pressure
(MPa)
Pd
Standard
2.72
Cooling
Overload
3.57
Low load
1.89
Standard
2.58
Heating
Overload
3.49
Low load
2.30
4 poles are provided to this compressor.
*
The compressor frequency (Hz) measured with a clamp meter is 2 times of revolutions (rps) of the compressor.
Refrigerant pipe
at gas side
Outer dia. ØA
Pd
Packed valve
Outer dia. ØA
Strainer
4-way valve
(STF-0213Z)
Muffler
Ø25 × L210
Ø25 × L160
Pipe surface temperature (°C)
Discharge
Suction
Ps
(TD)
(TS)
0.93
74
12
1.10
80
21
0.74
34
7
0.68
72
4
1.22
79
19
0.25
91
–17
Indoor unit
Air heat exchanger
TC sensor
Outdoor unit
TO sensor
TE
sensor
Heat exchanger Ø8
2 row 30 stages
FP1.3 flat fin
Indoor heat Outdoor heat
exchanger
exchanger
(TC)
(TE)
11
40
17
52
2
12
41
2
55
16
37
–19
– 40 –
RAV-SP800AT-E
TCJ
sensor
Refrigerant pipe
at liquid side
Outer dia. ØB
Packed valve
Outer dia. ØB
Modulating (PMV)
(SKV-18D26)
Strainer
Capillary
Ø3×Ø2×
L530
R410A 2.1 kg
Indoor/Outdoor
Compressor
temp. conditions
Indoor
revolutions per
(DB/WB) (°C)
fan
second (rps)
*
Indoor
55
HIGH
27/19
47
HIGH
32/24
24
LOW
18/15.5
62
HIGH
20/–
28
LOW
30/–
90
HIGH
15/–
Min.
Max.
5m
50m
Ps
Cooling
Heating
Outdoor
35/–
43/–
–5/–
7/6
24/18
–15/
(70%)