If experiencing this problem...
Intellifont
will not print:
Light print on the right side (facing
the printer) of the label:
Missing information in the printed
label:
Missing print on left or right side of
the label:
No power (all indicator lights are
'Off"):
56
Try this solution...
Intellifont
format is Little/Big Endian specific. The printer
uses Big Endian. Refer to your font supplier for information.
The Media Width Adjustment may be incorrectly adjusted;
see Section 5.3.
The Printhead or Platen Roller may be dirty or worn; clean
or call for service.
Check the label format for character placement outside the
dimensions of the label; all row/column values must allow
enough space for the height/length of the characters and
bar codes to be printed within the format size.
The available memory may have been exceeded by the
memory requirement of the label format. Try reducing the
memory allocated to either the internal module or
scaleable font caches; non-display printers see Section
3.4, display printers see Section 4.5.
If using serial communications, ensure that the interface
cable meets the requirements found in Section 2.1.
Information may be formatted outside the label dimensions.
Check your software program label size. For display printers
also check the values in the menu for Print Control / Column
Offset and Print Control / Custom Adjustments / Column
Offset; see Section 4.5.
Verify that the AC power cord connection has been made
at both the outlet and the printer; also, ensure the power
switch is 'On'.
Verify that the AC outlet is functioning, or try moving the
printer to another AC circuit.
The AC cord may be damaged; replace it.
The line fuse may be blown; call for service.