Standard Calibration - Datamax M-class Mark II Operator's Manual

Label printer datamax m-class mark ii
Hide thumbs Also See for M-class Mark II:
Table of Contents

Advertisement

3.5.2

Standard Calibration

The Standard Calibration can be performed using the DMXConfig Utility, (see section 3.4 for more
information on DMXConfig) and using the front panel buttons (see Appendix C for more
information). On display equipped printers the Standard Calibration routine can also be initiated
via the printer's menu, see section 4.5. Once you have installed the DMXConfig utility and the
printer is properly loaded with media:
1. Connect the host to the printer with a
serial or parallel cable.
2. Turn on the printer.
3. Launch the DMXConfig utility.
4. Query the printer by using the 'Query
Printer' toolbar button (top-left). This will
connect to the printer and get the current
printer settings.
5. Select the "Sensor Calibration" Tab and
then click the "Media Calibration Wizard"
button. When prompted click "OK" to start
the calibration wizard.
6. The Calibration Wizard will now prompt
you to 'Load Stock'. Be sure the media is
properly loaded in the printer. Close the
printhead and click "OK".
20
Chapter 3 - Printer Operation