Datamax M-class Mark II Operator's Manual page 48

Label printer datamax m-class mark ii
Hide thumbs Also See for M-class Mark II:
Table of Contents

Advertisement

SPEED
COMMANDS
ENABLED
DISABLED
TOF SENSING
COMMANDS
ENABLED
DISABLED
SYMBOL SET
COMMAND
ENABLED
DISABLED
CNTRL-CODES
(DATA)
ENABLED
DISABLED
STX-V SW
SETTINGS
ENABLED
DISABLED
MAX LENGTH
COMMAND
ENABLED
DISABLED
OPTION
FEEDBACK
DISABLED
SCANNER
RFID HEX
RFID ASCII
PROCESS SOH
(DATA)
ENABLED
DISABLED
42
Determines the way DPL Print, Feed, Slew, and Reverse commands are handled,
where:
Processes commands normally. (Default Setting)
Ignores DPL speed commands; instead, the speeds are controlled via the menu
setting.
Determines the way in which DPL Gap, Continuous, and Reflective commands are
handled, where:
Processes commands normally. (Default Setting)
Ignores DPL TOF commands; instead, TOF is controlled via the menu setting.
Determines the way in which DPL Single and Double Symbol Set commands are
handled, where:
Processes commands normally. (Default Setting)
Ignores DPL Symbol Set commands; instead, the Symbol Set selection is controlled
via the menu setting.
Determines the way in which DPL SOH, STX, CR, ESC, and ^ codes are handled,
where:
Processes commands normally. (Default Setting)
Ignores DPL Control Codes; instead, the control code functions are established via
the menu setting.
Determines the way in which the DPL <STX>V command is handled, where:
Processes commands normally. (Default Setting)
Ignores the option-enable command; instead, the option selections are controlled
via menu settings.
Determines the way in which the DPL <STX>M command is handled, where:
Processes commands normally. (Default Setting)
Ignores the maximum label length command; instead, Maximum Label Length is
controlled via the menu setting.
Allows feedback characters from an optional device to be returned to the host
device, in the format of: <A;B;C;D;E;F>[CR]
Where:
A
Is the device type: R = RFID; and, S = Linear Scanner
-
B
Is the resulting status: C = entire label complete; F = faulted (failed)
-
label; and, U = unknown
C
Is the number of expected reads for bar codes or tags, given in two
-
characters.
D
Is the number of good reads for bar codes or tags, given in two characters.
-
E
Is the printer's internal Job and Sub Job Identifier, given in four characters
-
each.
F
Is the data that was read, delimited with semicolons (;) on multiple reads.
-
No data is reported. (Default Setting)
Linear Scanner information is reported.
RFID information is reported in hexadecimal format.
RFID information is reported in an ASCII format.
Determines the way the printer responds to an Immediate Command (e.g., Get
Status, Module Storage, etc.), where:
Operations are interrupted upon receipt to process the command.
Processes commands normally. (Default Setting)