Datamax M-class Mark II Operator's Manual page 38

Label printer datamax m-class mark ii
Hide thumbs Also See for M-class Mark II:
Table of Contents

Advertisement

DSFID VALUE
DSFID LOCK
EAS VALUE
AUDIO
INDICATOR
ERASE ON
FAULT
UHF SETTINGS *
TAG TYPE
TAG DATA
SIZE
POWER
ADJUST
KILL CODE
ACCESS
CODE
GEN 2 LOCK
ACTION
LOCK AFTER
WRITE *
ENABLED
DISABLED
RETRY
ATTEMPTS *
(0 - 9)
3
PERFORM
CALIBRATION *
YES
NO
SET DEFAULTS *
32
Data Storage Format Identifier (00 - FF), where 00 is the default value.
Data Storage Format Identifier lock (ENABLED / DISABLED), where DISABLED is
the default setting.
Electronic Article Surveillance value (00 - FF), where 00 is the default value.
Controls the buzzer (ENABLED / DISABLED), where DISABLED is the default
setting.
Erases the tag when errors are detected (ENABLED / DISABLED), where DISABLED
is the default setting.
Sets UHF tag parameters, as follows:
Sets the tag type:
EPC 0
EPC 0+ MATRICS
EPC 0+ IMPINJ
EPC 1
UCODE EPC 1.19
EM 4022/1222
GEN 2 (Is the default setting.)
Sets the tag data size:
96-BIT (Is the default setting.)
64-BIT
Adjusts the applied power.
Code used to permanently deactivate the device:
B3
B2
B1 B0
00
00
00 00 (Is the default setting.)
Code used to protect the memory contents:
B3
B2
B1 B0
00
00
00 00 (Is the default setting.)
Sets the lock level (NONE, PERMALOCK, PWD-READ/WRITE, BOTH), where NONE is
the default setting.
Locks the tag after programming.
The tag will be locked.
No locking occurs (default setting).
Sets the number of retry attempts, where:
Zero to nine are the number of retries; and,
Is the default setting.
Allows the printer to establish the tag to transducer distance setting and nominal
RFID power requirements.
Initiates the process. The CALIBRATING RFID message will appear as the printer
feeds media to begin scanning for the RFID tag location. Once the location is
established, power calibration begins. Upon completion, the media will be retracted
to the TOF position; the calibrated position and power results (along with a brief
SUCCESS or FAILURE message) will be displayed; and, the printer's database will
be updated with the new calibration parameters.
Terminates the process.
Depending upon the RFID MODULE, selecting YES will return these settings:
If MODE = HF, then:
RFID POSITION = 1.10
HF SETTINGS:TAG TYPE = ISO 15693
RETRY ATTEMPTS = 3
--------------------------------------------------------------------------------------------
----
If MODE = UHF, then:
RFID POSITION = 1.10
UHF SETTINGS:TAG TYPE = GEN 2; TAG DATA SIZE = 96-BIT
RETRY ATTEMPTS = 3
Chapter 4 – Menu System

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents