2. Simulation code list

For sub codes marked with "*", only display is provided. (Cannot be
executed.)
Code
Main
Sub
1
1
Used to check the operation of the scanner unit
and its control circuit.
2
Used to check the operation of sensor and
detector in the scanning (read) section and the
related circuit.
2
1
Used to check the operation of the SPF unit and
the related circuit.
2
Used to check the operation of sensors and
detectors in the SPF unit and the related circuit.
3
Used to check the operation of the loads in the
SPF unit and the control circuits.
3
2
Used to check the operation of sensor and
detector in the finisher and the related circuit.
3
Used to check the operation of the load in the
finisher and the control circuit.
6
Used to adjust the finisher jogger position.
7
Used to adjust the offset tray operations.
11
Used to check the operation of the shifter.
4
2
Used to check the operation of sensor and
detector in the option tray and the related circuit.
3
Used to check the operation of the load in the
option tray and the control circuit.
5
1
Used to check the operation of the display, LCD in
the operation panel, and control circuit.
2
Used to check the operation of the heater lamp
and the control circuit.
3
Used to check the operation of the copy lamp and
the control circuit.
6
1
Used to check the operation of the loads (clutches
and solenoids) in the paper transport system and
the control circuit.
2
Used to check the operation of each fan motor and
its control circuit.
7
1
Used to set the aging operation conditions.
6
Used to set the cycle of intermittent aging.
8
Used to set the display of the warm-up time.
8
1
Used to check and adjust the operation of the
developing bias voltage in each copy mode and
the control circuit.
2
Used to check and adjust the operation of the main
charger grid voltage (high mode) in each copy
mode and the control circuit.
3
Used to check and adjust the operation of the main
charger grid voltage (low mode) in each copy
mode and the control circuit.
10
Used to check and adjust the operation of the
developing bias voltage in each printer mode and
the control circuit.
11
Used to check and adjust the operation of the main
charger grid voltage (high mode) in each printer
mode and the control circuit.
12
Used to check and adjust the operation of the main
charger grid voltage (low mode) in each printer
mode and the control circuit.
13
Used to check and adjust the operation of the
developing bias voltage in FAX mode and the
control circuit.
14
Used to check and adjust the operation of the main
charger grid voltage (high mode) in FAX mode and
the control circuit.
15
Used to check and adjust the operation of the main
charger grid voltage (low mode) in FAX mode and
the control circuit.
Function
AR-5127 SIMULATION 8 - 2
Code
Main
Sub
9
1
Used to check and adjust the operation of the load
(motor) in the duplex section and the control
circuit.
4
Used to adjust the rotation speed of the duplex
motor.
5
Used to adjust the switch back time of the duplex
motor.
10
0
Used to check the operation of the toner motor and
its control circuit.
14
0
Used to cancel excluding the self-diag U2/PF
troubles.
16
0
Used to cancel the self-diag U2 trouble.
17
0
Used to cancel the self diag "PF" trouble.
21
1
Used to set the maintenance cycle.
22
1
Used to check the counter value of each section.
2
Used to check the total numbers of misfeed and
troubles. (When the number of misfeed is
considerably great, it is judged as necessary for
repair. The misfeed rate is obtained by dividing this
count value with the total counter value.)
3
Used to check the misfeed positions and the
number of misfeed at each position. (When the
number of misfeed is considerably great, it can be
judged as necessary for repair.)
4
Used to check the total trouble (self diag) history.
5
Used to check the ROM version of each unit
(section).
7
Used to display the key operator code
8
Used to check the number of use of the staple, the
SPF, and scanning.
9
Used to check the number of use of each paper
feed section. (the number of prints)
10
Used to check the system configuration.
11
FAX related counter display
12
Used to check the misfeed positions and the
number of misfeed at each position. (When the
number of misfeed is considerably great, it can be
judged as necessary for repair.)
19
Used to display the scanner mode counter.
24
1
Used to clear the misfeed counter, the misfeed
history, the trouble counter, and the trouble history.
(The counters are cleared after completion of
maintenance.)
2
Used to clear the number of use (the number of
prints) of each paper feed section.
3
Used to clear the number data of use of the staple,
the SPF and scanning.
4
Used to reset the maintenance counter.
5
Used to reset the developer counter. (The
developer counter of the DV unit which is installed
is reset.)
6
Used to reset the copy counter.
7
Used to clear the OPC drum (membrane
decrease) correction counter. (This simulation is
executed when the OPC drum is replaced.
9
Used to clear the printer print counter. (The
counter is cleared after completion of
maintenance.)
10
FAX related counter clear
15
Used to clear the scanner mode counter.
25
1
Used to check the operation of the main drive
(excluding the scanner section) and to check the
operation of the toner concentration sensor. (The
toner concentration sensor output can be
monitored.)