Signal line name
FDR A, FDR B, FDR XA, FDR XB
DA_FDRMOT
FDR_A, FDR_B, FDR_XA, FDR_XB DRIVE ASSY FEEDER exciting signal
NO OPF(L)+3.3VDC
Outline of DRIVE ASSY FEEDER
Motor type: Hybrid stepping motor
Stepping angle:1.8° ± 0.09°
Winding resistance:6.4
Exciting sequence:(*: Exciting)
DRIVE ASSY FEEDER drive control signal
OPTION FEEDER fail detection signal (High: Fail, Low: Normal)
± 10% / phase (25°C)
Phase
1
FDR_A
FDR_B
FDR_XA
*
FDR_XB
*
Chapter 7 Wiring Diagrams and Signal Information
Description
Step (2 phases)
2
3
*
*
*
*
4
*
*