Chapter 2 Hardware Installation and Connection
Note: Do NOT block the ventilation holes. Leave space between devices when stacking.

2.3 Mounting the Switch on a Rack

The Switch can be mounted on an EIA standard size, 19-inch rack or in a wiring closet with other
equipment. Follow the steps below to mount your Switch on a standard EIA rack using a rack-
mounting kit.

2.3.1 Rack-mounted Installation Requirements

• Two mounting brackets.
• Eight M3 flat head screws and a #2 Philips screwdriver.
• Four M5 flat head screws and a #2 Philips screwdriver.
Failure to use the proper screws may damage the unit.
2.3.1.1 Precautions
• Make sure the rack will safely support the combined weight of all the equipment it contains.
• Make sure the position of the Switch does not make the rack unstable or top-heavy. Take all
necessary precautions to anchor the rack securely before installing the unit.

2.3.2 Attaching the Mounting Brackets to the Switch

Position a mounting bracket on one side of the Switch, lining up the four screw holes on the bracket
1
with the screw holes on the side of the Switch.
Figure 4 Attaching the Mounting Brackets
Using a #2 Philips screwdriver, install the M3 flat head screws through the mounting bracket holes
2
into the Switch.
Repeat steps
3
You may now mount the Switch on a rack. Proceed to the next section.
4
24
1
and
2
to install the second mounting bracket on the other side of the Switch.