Setting The Ocp Control Level; Camera Assignment - GRASS VALLEY OCP 400 User Manual

Operational control panel
Hide thumbs Also See for OCP 400:
Table of Contents

Advertisement

Menu
OCP setup
page 7
OCP setup
page 8
OCP setup
page 9
OCP setup
page 10

3.3.1 Setting the OCP control level

The OCP menu system has three levels of control; Simple, Basic and Full. These levels
determine which functions are displayed. In the OCP setup menu move to the OCP Set item
and select S (simple), B (basic) or F (full).
Select the simple level to reduce the number of functions displayed to a minimum. Use
this level to protect against unintentional changes to critical parameters.
Select the basic level as the normal operational mode of the OCP . Use this level to prevent
set-up parameters from being displayed. This is the factory default level.
Select the full level to access all functions available on the OCP .

3.3.2 Camera assignment

The OCP can be assigned to an XCU/Base Station - camera combination by moving to the
CamNum item of the OCP setup menu. Select the camera number of the camera that you
want to control using the assignable rotary control. Press SELECT to confirm.
22
Selections
Function
CamNum2
Select secondary camera
number
SELECT
Connects to the secondary
camera.
Multi-Cam
Switches multi camera mode on
or off
ProgFunc1
Assigns a function to
programmable function1
ProgFunc2
Assigns a function to
programmable function 2
ProgFunc3
Assigns a function to
programmable function 3
ProgFunc4
Assigns a function to
programmable function 4
ProgFunc5
Assigns a function to
programmable function 5
ProgFunc6
Assigns a function to
programmable function 6
OCP Set
Selects the OCP control access
level
Reset OCP
Resets all local functions to
their default values.
Level
Possible values
1..99
Press button to connect to the
selected secondary camera
On, Off
Disabled, Gain +/-, ND Up/Dwn,
FX Up/Dwn
Disabled, Gain +/-, ND Up/Dwn,
FX Up/Dwn
Disabled, Dtl Lvl, Var Gain, Var
Ctemp, BlackStr, BlackStr Lvl,
Knee, Knee Slope, Knee Point
same as above
same as above
same as above
S
Simple (S), Basic (B), Full (F)
F
Press button to execute reset
OCP 400 Operational Control Panel User's Guide (v12.0)
Chapter 3 - Setup

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents