17. Malfunction code
Display message
0300
0310
0500
0502
0503
0510
0520
0F50
0F52
0F53
0F54
0F55
13C0
13DD
13F0
3C00
3C10
13E2
282
Misfeed location
• The polygon motor does not rotate evenly even
after the lapse of a given period of time after it
has been started.
Polygon motor
malfunction
• The motor lock signal remains HIGH for a given
period of consecutive time while the polygon
motor is being rotated.
• The SOS signal is not detected within a given
Laser malfunction
period of time after the output of the laser has
been started.
• The thermistor /1 does not detect the specified
Heating roller
temperature and the warm-up cycle is not com-
warm-up failure
pleted even after the lapse of a given period of
time after the cycle has been started.
• The temperature detected by the thermistor
Thermistor open-
does not reach a predetermined level even after
circuit failure
the lapse of a given period time after the warm-
up cycle has been started.
• The difference between the temperature
Thermistor resis-
detected by thermistor/1 and that detected by
tance failure
thermistor/2 exceeds a predetermined value.
Abnormally low
• The temperature detected by the thermistor /1
heating roller tem-
remains lower than the specified value for a
perature
given period of time or longer.
• The temperature detected by the thermistor /1
Abnormally high
remains higher than the specified value for a
heating roller tem-
given period of time or longer.
perature
• The heater lamp remains ON for a given period
of time or longer.
OHP sensor mal-
• It is determined that the OHP sensor is faulty
function
through a check made at the end of the predrive.
Toner level sensor /
• An error occurs on the toner level sensor board
Y malfunction
(TLSB).
Toner level sensor /
M malfunction
Toner level sensor /
C malfunction
Toner level sensor /
K malfunction
Print control board
• A communication error occurs in print control
malfunction
board (PRCB).
• The printer determines that EEPROM is yet to
Backup data error
be mounted when the main power switch is
turned ON.
Engine control fail-
• An undefined malfunction occurs in the engine
ure
section (PRCB, etc.).
• Contact the responsible people of KONICA
Trouble related to
MINOLTA when not returning in power switch
security
OFF/ON.
Engine flash ROM
• Flash ROM writing is found faulty during a
write error
check.
Field Service Ver. 1.0 May 2008