Chapter 4 — ESim Commands
Errors: If data is not suitable to optional parameters, Error 01 (syntax error)
56
Masking Parameter Descriptions (continued)
Parameter
Description
o
Rotation:
0 = 0° rotation clockwise. Default.
1 = 90° rotation clockwise.
2 = 180° rotation clockwise.
3 - 270° rotation clockwise.
s
Set correction level:
L = 7% (default)
M = 15% (default)
Q = 25% (default)
H = 30% (default)
x
Masking factor 0-7 or 8 (auto).
Default is 8.
y
Cell pixel size magnification 02-64.
Default is 10.
"DATA"
Represents a fixed data field. Maximum data
length is relative chosen model type and data
mode, but is limited to approximately 780
bytes. Ordinary string controls, like
\\for\and\"for".
occurs.
If data is too long or out of range, Error 03 (data length error) occurs.
If data does not fit in area specified, Error 50 occurs.
Example
N
b40,40,Q,sM,x1,"ABCDEFGHIJKLMNOPQRSTUVWHYZ123456
789012345678901234ABCDEFGHIJKLMNOPQ
RSTUVWHYZ1234"
P1