Error Responses and Codes Reported When Command US Is On (continued)
Error
Error
Code
Type
Description
17
C
Out of ribbon,
marked with Rnnn =
Number of remaining
labels.
50
A
Does not fit in area
specified.
51
A
Data length too long RED
61
D
High motor
temperature
62
D
High printhead
temperature
71
F
Wait after default
setup.
72
F
Flashing not
completed
73
F
Download error
81
B
Cutter jammed or not
installed.
89
G
Dump mode (after
auto-detection).
92
H
Pause printing mode BLNK
94
G
Autosensing mode
98
G
Download mode (not
public use)
99
Other errors
ESim for the PC4 and PF8 Printers Programmer's Reference Manual
LED
Serial
RED
<NAK>07Rnnn
[XOFF]
RED
<NAK>50[XOFF
]
<NAK>51[XOFF
]
BLNK
<NAK>61[XOFF
RED
]
BLNK
<NAK>62[XOFF
RED
]
GRN
-
RED
<NAK>72[XOFF
]
RED
<NAK>73[XOFF
]
BLNK
<NAK>81[XOFF
RED
]
GRN
<NAK>89[XOFF
]
<NAK>92[XOFF
GRN/ORA
]
OFF
<NAK>94[XOFF
]
<NAK>99[XOFF
]
Chapter A — Error Handling
Response to
Command ^ee
17<CRLF>
50<CRLF>
51<CRLF>
61<CRLF>
62<CRLF>
71<CRLF>
72<CRLF>
73<CRLF>
81<CRLF>
89<CRLF>
92<CRLF>
94<CRLF>
99<CRLF>