Toshiban lämmitys- ja jäähdytyslaitteiden jälleenmyyjä pääkaupunkiseudulla on Jäähdytinpalvelu RefGroup Oy
No.
Part name
Fan motor
1) Perform work of item
2) Perform work of item
3) Loosen set screw of the cross flow fan from the
discharge port.
4) Remove the bushing (right).
5) Take off two fixing screws of the motor band (right).
6) Pull out the motor band (right) and the fan motor
outward.
* Caution at reassembly
• Determine position of the fan motor so that connec-
tor of the fan motor enters in the positioning rib of
the motor band (right).
Cross flow
1) Perform works of items
fan
2) Loosen set screw of the cross flow fan from the
discharge port.
3) Take off two fixing screws at the left side of the end
plate of the heat exchanger, and then take off two
fixing screws of the bearing base.
4) Lift up slightly the left side of the heat exchanger to
remove the bearing base.
5) Lift up the left side of the heat exchanger toward
you to remove the cross flow fan.
* Caution at reassembly
• Mount the cross flow fan so that the left end of the
first joint from right of the drift fan matches with the
left end of the positioning rib of the rear main body.
Procedure

.
ƒ
.
Bushing (right)
Push this
part upward

ƒ
and
– 149 –
www.ilmalämpöpumput.com
Fixing screws
.
Fixing screw
Positioning rib
Remarks
Set screw
Cross fan